English conectarse Registrarse Catalog Browser Contact Us
Experto global en cableado y en sistemas de cableado

Sobre Nexans

Productos y Soluciones

Servicios al cliente

Trabaje en Nexans

Noticias y prensa

IR

Outside Plant Single Armor Double Jacket

Bookmark Imprimir Contactanos
Outside Plant Single Armor Double Jacket Berk-Tek’s Outside Plant Single Armor Double Jacket Loose Tube fiber optic cables are designed for installation in harsh enviroments such as direct burial, aerial lashing, conduit and pathways that are subjected to wide temperature variations. The Armored Outside Plant product incorporates a corrugated steel armor tape between two jackets surrounding the core and is offered with 2 - 216 fibers per cable. These cables are thoroughly tested and verified to Telcordia GR-20 and ICEA-640 for outside cabling systems.
Estándares
Internacional  EN 50173; ISO/IEC 11801
Nacional  ANSI/ICEA S-87-640; ANSI/TIA-568-C.3; Telcordia GR-20; Telcordia GR-409
Descripción

Berk-Tek's Outdoor Single Armor Double Jacket Loose Tube cables are available in multimode, single-mode and GIGAlite™ fibers.

 

Buffer Tube Construction

Gel-filled tubes containing up to 12, 250 µm, individually colored fibers.

 

Outdoor Consideration

Berk-Tek recommends that loose tube cables be utilized in an outside plant installation environment. Loose tube cables are especially recommended if the interbuilding conduit system is likely to fill with water.

 

Applications

Berk-Tek's Outdoor Loose Tube fiber optic cable is intended for all high speed data applications, including:

  • 10BASE-FL
  • 100BASE-SX/100BASE-FX
  • ATM 155/ATM 622
  • 1000BASE-SX/1000BASE-LX
  • Fibre Channel 1.062/2.125
  • 10GBASE-SR/SW
  • 10GBASE-LX4
  • 40/100 GbE

 

Features

  • High tensile strength, crush resistant and small diameter design. 
  • Single-mode, multimode and hybrid design options available.  
  • Corrugated steel armor provides crush and rodent resistance.
  • Fully water-blocked core using dry water blocking system.  
  • Also available in Low Smoke Zero Halogen and Armored designs.

 

Benefits

  • Provides for greater pulling distances thus reducing installation time.
  • Broad design selection allows for mix and match of fiber components to specific networking applications.
  • One cable design meeting all structured cabling applications .
  • Long-term reliability.
  • Low cable plant maintenance, ease of installation.
  • Reduce network costs.

 TOP
Características
Características de construcción
Cubierta exterior Polyethylene  
Características de uso
RoHS conform Yes  
Temperatura ambiente de utilización (rango) -40 .. 75°C  
Temperatura ambiente de instalación (rango) -30 .. 60°C  
Storage temperature, range -60 .. 85°C  

 TOP
Búsqueda parametrizada
Optical performance  
Number of optical fibres  
Solicita
Restaurar
Su selección   88/88
Selecciona todos los artículos Ref. Nexans Nombre
OPA012CB3510/25 12 x OM1 Outside Plant Loose Tube Single Armor
OPAD12B012CB3510/25 12 x OM1 Outside Plant Loose Tube Single Armor
OPA012GB3510/25 12 x OM1+ Outside Plant Loose Tube Single Armor
OPAD12B012GB3510/25 12 x OM1+ Outside Plant Loose Tube Single Armor
OPA012ZB3515/55 12 x OM2 Outside Plant Loose Tube Single Armor
OPAD12B012ZB3515/55 12 x OM2 Outside Plant Loose Tube Single Armor
OPA012LB3010/75 12 x OM2+ Outside Plant Loose Tube Single Armor
OPAD12B012LB3010/75 12 x OM2+ Outside Plant Loose Tube Single Armor
OPA012EB3010/25 12 x OM3 Outside Plant Loose Tube Single Armor
OPAD12B012EB3010/25 12 x OM3 Outside Plant Loose Tube Single Armor
OPA012FB3010/F5 12 x OM4 Outside Plant Loose Tube Single Armor
OPAD12B012FB3010/F5 12 x OM4 Outside Plant Loose Tube Single Armor
OPA012XB3010/X5 12 x OM4+ Outside Plant Loose Tube Single Armor
OPAD12B012XB3010/X5 12 x OM4+ Outside Plant Loose Tube Single Armor
OPA012AB0403 12 x OS2 Outside Plant Loose Tube Single Armor
OPAD12B012AB0403 12 x OS2 Outside Plant Loose Tube Single Armor
OPAD12B144CB3510/25 144 x OM1 Outside Plant Loose Tube Single Armor
OPAD12B144GB3510/25 144 x OM1+ Outside Plant Loose Tube Single Armor
OPAD12B144ZB3515/55 144 x OM2 Outside Plant Loose Tube Single Armor
OPAD12B144LB3010/75 144 x OM2+ Outside Plant Loose Tube Single Armor
OPAD12B144EB3010/25 144 x OM3 Outside Plant Loose Tube Single Armor
OPAD12B144FB3010/F5 144 x OM4 Outside Plant Loose Tube Single Armor
OPAD12B144XB3010/X5 144 x OM4+ Outside Plant Loose Tube Single Armor
OPAD12B144AB0403 144 x OS2 Outside Plant Loose Tube Single Armor
OPAD12B018CB3510/25 18 x OM1 Outside Plant Loose Tube Single Armor
OPAD12B018GB3510/25 18 x OM1+ Outside Plant Loose Tube Single Armor
OPAD12B018ZB3515/55 18 x OM2 Outside Plant Loose Tube Single Armor
OPAD12B018LB3010/75 18 x OM2+ Outside Plant Loose Tube Single Armor
OPAD12B018EB3010/25 18 x OM3 Outside Plant Loose Tube Single Armor
OPAD12B018FB3010/F5 18 x OM4 Outside Plant Loose Tube Single Armor
OPAD12B018XB3010/X5 18 x OM4+ Outside Plant Loose Tube Single Armor
OPAD12B018AB0403 18 x OS2 Outside Plant Loose Tube Single Armor
OPA002CB3510/25 2 x OM1 Outside Plant Loose Tube Single Armor
OPA002GB3510/25 2 x OM1+ Outside Plant Loose Tube Single Armor
OPA002ZB3515/55 2 x OM2 Outside Plant Loose Tube Single Armor
OPA002LB3010/75 2 x OM2+ Outside Plant Loose Tube Single Armor
OPA002EB3010/25 2 x OM3 Outside Plant Loose Tube Single Armor
OPA002FB3010/F5 2 x OM4 Outside Plant Loose Tube Single Armor
OPA002XB3010/X5 2 x OM4+ Outside Plant Loose Tube Single Armor
OPA002AB0403 2 x OS2 Outside Plant Loose Tube Single Armor
OPAD12B216CB3510/25 216 x OM1 Outside Plant Loose Tube Single Armor
OPAD12B216GB3510/25 216 x OM1+ Outside Plant Loose Tube Single Armor
OPAD12B216ZB3515/55 216 x OM2 Outside Plant Loose Tube Single Armor
OPAD12B216LB3010/75 216 x OM2+ Outside Plant Loose Tube Single Armor
OPAD12B216EB3010/25 216 x OM3 Outside Plant Loose Tube Single Armor
OPAD12B216FB3010/F5 216 x OM4 Outside Plant Loose Tube Single Armor
OPAD12B216XB3010/X5 216 x OM4+ Outside Plant Loose Tube Single Armor
OPAD12B216AB0403 216 x OS2 Outside Plant Loose Tube Single Armor
OPAD12B024CB3510/25 24 x OM1 Outside Plant Loose Tube Single Armor
OPAD12B024GB3510/25 24 x OM1+ Outside Plant Loose Tube Single Armor
OPAD12B024ZB3515/55 24 x OM2 Outside Plant Loose Tube Single Armor
OPAD12B024LB3010/75 24 x OM2+ Outside Plant Loose Tube Single Armor
OPAD12B024EB3010/25 24 x OM3 Outside Plant Loose Tube Single Armor
OPAD12B024FB3010/F5 24 x OM4 Outside Plant Loose Tube Single Armor
OPAD12B024XB3010/X5 24 x OM4+ Outside Plant Loose Tube Single Armor
OPAD12B024AB0403 24 x OS2 Outside Plant Loose Tube Single Armor
OPA004CB3510/25 4 x OM1 Outside Plant Loose Tube Single Armor
OPA004GB3510/25 4 x OM1+ Outside Plant Loose Tube Single Armor
OPA004ZB3515/55 4 x OM2 Outside Plant Loose Tube Single Armor
OPA004LB3010/75 4 x OM2+ Outside Plant Loose Tube Single Armor
OPA004EB3010/25 4 x OM3 Outside Plant Loose Tube Single Armor
OPA004FB3010/F5 4 x OM4 Outside Plant Loose Tube Single Armor
OPA004XB3010/X5 4 x OM4+ Outside Plant Loose Tube Single Armor
OPA004AB0403 4 x OS2 Outside Plant Loose Tube Single Armor
OPAD12B048CB3510/25 48 x OM1 Outside Plant Loose Tube Single Armor
OPAD12B048GB3510/25 48 x OM1+ Outside Plant Loose Tube Single Armor
OPAD12B048ZB3515/55 48 x OM2 Outside Plant Loose Tube Single Armor
OPAD12B048LB3010/75 48 x OM2+ Outside Plant Loose Tube Single Armor
OPAD12B048EB3010/25 48 x OM3 Outside Plant Loose Tube Single Armor
OPAD12B048FB3010/F5 48 x OM4 Outside Plant Loose Tube Single Armor
OPAD12B048XB3010/X5 48 x OM4+ Outside Plant Loose Tube Single Armor
OPAD12B048AB0403 48 x OS2 Outside Plant Loose Tube Single Armor
OPA006CB3510/25 6 x OM1 Outside Plant Loose Tube Single Armor
OPA006GB3510/25 6 x OM1+ Outside Plant Loose Tube Single Armor
OPA006ZB3515/55 6 x OM2 Outside Plant Loose Tube Single Armor
OPA006LB3010/75 6 x OM2+ Outside Plant Loose Tube Single Armor
OPA006EB3010/25 6 x OM3 Outside Plant Loose Tube Single Armor
OPA006FB3010/F5 6 x OM4 Outside Plant Loose Tube Single Armor
OPA006XB3010/X5 6 x OM4+ Outside Plant Loose Tube Single Armor
OPA006AB0403 6 x OS2 Outside Plant Loose Tube Single Armor
OPAD12B072CB3510/25 72 x OM1 Outside Plant Loose Tube Single Armor
OPAD12B072GB3510/25 72 x OM1+ Outside Plant Loose Tube Single Armor
OPAD12B072ZB3515/55 72 x OM2 Outside Plant Loose Tube Single Armor
OPAD12B072LB3010/75 72 x OM2+ Outside Plant Loose Tube Single Armor
OPAD12B072EB3010/25 72 x OM3 Outside Plant Loose Tube Single Armor
OPAD12B072FB3010/F5 72 x OM4 Outside Plant Loose Tube Single Armor
OPAD12B072XB3010/X5 72 x OM4+ Outside Plant Loose Tube Single Armor
OPAD12B072AB0403 72 x OS2 Outside Plant Loose Tube Single Armor
Añade a favoritos

 TOP
Sheath Colors

Fiber Type

ISO-TIA
Standard

Effective Modal
BW @ 850 nm

Overfilled Launch
BW @ 850 nm

Attenuation
@ 850 nm

Attenuation
@ 1300 nm

Attenuation
@ 1550 nm

Sheath Color

AB

OS2

NS

NS

NS

0.4 dB/km

0.3 dB/km

Black

CB

OM1

200 MHz-km

200 MHz-km

3.5 dB/km

1.0 dB/km

NS

Black

GB

OM1

500 MHz-km

350 MHz-km

3.5 dB/km

1.0 dB/km

NS

Black

ZB

OM2

500 MHz-km

500 MHz-km

3.5 dB/km

1.5 dB/km

NS

Black

LB

OM2+

950 MHz-km

700 MHz-km

3.0 dB/km

1.0 dB/km

NS

Black

EB

OM3

2000 MHz-km

1500 MHz-km

3.0 dB/km

1.0 dB/km

NS

Black

FB

OM4

4700 MHz-km

3500 MHz-km

3.0 dB/km

1.0 dB/km

NS

Black

XB

OM4+

4900 MHz-km

3675 MHz-km

3.0 dB/km

1.0 dB/km

NS

Black

NS = Not Specified


 TOP
Manufacturing Release

IMPORTANT NOTICE: This product specification is provided for informational purposes only in order to illustrate typical product constructions, applications and/or methods of installation. Because conditions of actual installation and use are unique and will vary, Berk-Tek makes no representation or warranty as to the reliability, accuracy or completeness of this data, even if Berk-Tek is aware of the product's intended use or purpose. Furthermore, this data does not constitute, nor should it be regarded or relied upon, as professional engineering advice. Installation of cable should only be done by qualified personnel and in conformance with all safety, electrical and other applicable codes, standards, rules or regulations. Appropriate and correct product selection, installation and use, and compliance with all such codes, standards, rules and regulations, is a customer/end-user responsibility. Product specifications, standards, programs or services are subject to improvement or changes without notice. Berk-Tek accepts no liability for typographical errors, technical inaccuracies, omissions or misuse of the information contained herein. Changes will be periodically made to address any such issues.


 TOP
Información relacionada
Outside Plant Single Armor Double Jacket   Fiber Specifications PS0309.revR (35 kB)
Outside Plant Single Armor Double Jacket   Breakout Kits - Loose Tube (343 kB)

Nexans © copyright 2001 - 2012   Legal Notice | Contact Us | Site Map