English conectarse Registrarse Catalog Browser Contact Us
Experto global en cableado y en sistemas de cableado

Sobre Nexans

Productos y Soluciones

Servicios al cliente

Trabaje en Nexans

Noticias y prensa

IR

Interconnect Plenum Cabling

Bookmark Imprimir Contactanos
Interconnect Plenum Cabling Berk-Tek's Interconnect Tight Buffered Plenum fiber optic cable is designed for installation along plenums and in riser horizontal structured cabling applications.
Estándares
Internacional  EN 50173; ISO/IEC 11801
Nacional  ANSI/ICEA S-83-596; ANSI/TIA-568-C.3; Telcordia GR-409
Descripción

Berk-Tek's Plenum Interconnect Tight Buffered cables are available with standard multimode, single-mode, and GIGAliteTM optical fibers.

 

Construction

900 um buffered fibers surrounded by aramid yarns.  Sheathed using a special state-of-the-art, polymer material. 

All Dielectric. OFNP FT-6

 

Applications

Berk-Tek's Interconnect Tight Buffered Cable is intended for all high speed data applications including:

 

  • 10BASE-FL
  • 100BASE-SX/100BASE-FX
  • ATM 155/ATM 622
  • 1000BASE-SX/1000BASE-LX
  • Fibre Channel 1.062/2.125
  • 10GBASE-SR/SW
  • 10GBASE-LX4
  • 40/100 GbE

 

 

Features

  • Flexible, small diameter, 900 um tight buffered construction
  • High tensile strength and small diameter design
  • 1 through 4 fiber designs for patch cable and horizontal installations

 

 


 TOP
Características
Características de construcción
Tipo de cable Tight Buffered (TB)  
Cubierta exterior Plenum  
Características de uso
RoHS conform Yes  
Temperatura ambiente de utilización (rango) -20 .. 75°C  
Temperatura ambiente de instalación (rango) 0 .. 70°C  
Storage temperature, range -40 .. 85°C  

 TOP
Búsqueda parametrizada
Optical performance  
Number of optical fibres  
Solicita
Restaurar
Su selección   48/48
Selecciona todos los artículos Ref. Nexans Nombre
ICP001CB3510/25 1 x OM1 Interconnect Plenum Cable
MCP001CB3510/25 1 x OM1 Interconnect Plenum Cable - 1.6 mm
ICP001GB3510/25 1 x OM1+ Interconnect Plenum Cable
MCP001GB3510/25 1 x OM1+ Interconnect Plenum Cable - 1.6 mm
ICP001ZB3515/55 1 x OM2 Interconnect Plenum Cable
MCP001ZB3515/55 1 x OM2 Interconnect Plenum Cable - 1.6 mm
ICP001LB3010/75 1 x OM2+ Interconnect Plenum Cable
MCP001LB3010/75 1 x OM2+ Interconnect Plenum Cable - 1.6 mm
ICP001EB3010/25 1 x OM3 Interconnect Plenum Cable
MCP001EB3010/25 1 x OM3 Interconnect Plenum Cable - 1.6 mm
ICP001FB3010/F5 1 x OM4 Interconnect Plenum Cable
MCP001FB3010/F5 1 x OM4 Interconnect Plenum Cable - 1.6 mm
ICP001XB3010/X5 1 x OM4+ Interconnect Plenum Cable
MCP001XB3010/X5 1 x OM4+ Interconnect Plenum Cable - 1.6 mm
ICP001AB0707 1 x OS2 Interconnect Plenum Cable
MCP001AB0707 1 x OS2 Interconnect Plenum Cable - 1.6 mm
ICP002CB3510/25 2 x OM1 Interconnect Plenum Round Cable
ICP0X0CB3510/25 2 x OM1 Interconnect Plenum Zipcord Cable
MCP0X0CB3510/25 2 x OM1 Interconnect Plenum Zipcord Cable - 1.6 mm
ICP002GB3510/25 2 x OM1+ Interconnect Plenum Round Cable
ICP0X0GB3510/25 2 x OM1+ Interconnect Plenum Zipcord Cable
MCP0X0GB3510/25 2 x OM1+ Interconnect Plenum Zipcord Cable - 1.6 mm
ICP002ZB3515/55 2 x OM2 Interconnect Plenum Round Cable
ICP0X0ZB3515/55 2 x OM2 Interconnect Plenum Zipcord Cable
MCP0X0ZB3515/55 2 x OM2 Interconnect Plenum Zipcord Cable - 1.6 mm
ICP002LB3010/75 2 x OM2+ Interconnect Plenum Round Cable
ICP0X0LB3010/75 2 x OM2+ Interconnect Plenum Zipcord Cable
MCP0X0LB3010/75 2 x OM2+ Interconnect Plenum Zipcord Cable - 1.6 mm
ICP002EB3010/25 2 x OM3 Interconnect Plenum Round Cable
ICP0X0EB3010/25 2 x OM3 Interconnect Plenum Zipcord Cable
MCP0X0EB3010/25 2 x OM3 Interconnect Plenum Zipcord Cable - 1.6 mm
ICP002FB3010/F5 2 x OM4 Interconnect Plenum Round Cable
ICP0X0FB3010/F5 2 x OM4 Interconnect Plenum Zipcord Cable
MCP0X0FB3010/F5 2 x OM4 Interconnect Plenum Zipcord Cable - 1.6 mm
ICP002XB3010/X5 2 x OM4+ Interconnect Plenum Round Cable
ICP0X0XB3010/X5 2 x OM4+ Interconnect Plenum Zipcord Cable
MCP0X0XB3010/X5 2 x OM4+ Interconnect Plenum Zipcord Cable - 1.6 mm
ICP002AB0707 2 x OS2 Interconnect Plenum Round Cable
ICP0X0AB0707 2 x OS2 Interconnect Plenum Zipcord Cable
MCP0X0AB0707 2 x OS2 Interconnect Plenum Zipcord Cable - 1.6 mm
ICP004CB3510/25 4 x OM1 Interconnect Plenum Cable
ICP004GB3510/25 4 x OM1+ Interconnect Plenum Cable
ICP004ZB3515/55 4 x OM2 Interconnect Plenum Cable
ICP004LB3010/75 4 x OM2+ Interconnect Plenum Cable
ICP004EB3010/25 4 x OM3 Interconnect Plenum Cable
ICP004FB3010/F5 4 x OM4 Interconnect Plenum Cable
ICP004XB3010/X5 4 x OM4+ Interconnect Plenum Cable
ICP004AB0707 4 x OS2 Interconnect Plenum Cable
Añade a favoritos

 TOP
Sheath Colors

Fiber Type

ISO-TIA
Standard

Effective Modal
BW @ 850 nm

Overfilled Launch
BW @ 850 nm

Attenuation
@ 850 nm

Attenuation
@ 1300 nm

Attenuation
@ 1550 nm

Sheath Color

AB

OS2

NS

NS

NS

0.7 dB/km

0.7 dB/km

Yellow

CB

OM1

200 MHz-km

200 MHz-km

3.5 dB/km

1.0 dB/km

NS

Orange

GB

OM1+

500 MHz-km

350 MHz-km

3.5 dB/km

1.0 dB/km

NS

Orange

ZB

OM2

500 MHz-km

500 MHz-km

3.5 dB/km

1.5 dB/km

NS

Orange

LB

OM2+

950 MHz-km

700 MHz-km

3.0 dB/km

1.0 dB/km

NS

Orange

EB

OM3

2000 MHz-km

1500 MHz-km

3.0 dB/km

1.0 dB/km

NS

Aqua

FB

OM4

4700 MHz-km

3500 MHz-km

3.0 dB/km

1.0 dB/km

NS

Aqua

XB

OM4+

4900 MHz-km

3675 MHz-km

3.0 dB/km

1.0 dB/km

NS

Aqua

NS = Not Specified


 TOP
Manufacturing Release

IMPORTANT NOTICE: This product specification is provided for informational purposes only in order to illustrate typical product constructions, applications and/or methods of installation. Because conditions of actual installation and use are unique and will vary, Berk-Tek makes no representation or warranty as to the reliability, accuracy or completeness of this data, even if Berk-Tek is aware of the product's intended use or purpose. Furthermore, this data does not constitute, nor should it be regarded or relied upon, as professional engineering advice. Installation of cable should only be done by qualified personnel and in conformance with all safety, electrical and other applicable codes, standards, rules or regulations. Appropriate and correct product selection, installation and use, and compliance with all such codes, standards, rules and regulations, is a customer/end-user responsibility. Product specifications, standards, programs or services are subject to improvement or changes without notice. Berk-Tek accepts no liability for typographical errors, technical inaccuracies, omissions or misuse of the information contained herein. Changes will be periodically made to address any such issues.