T1 - Telephone Exchange Cable

Bookmark Imprimir Contactanos
T1 - Telephone Exchange Cable Berk-Tek's T1 cables have been specially designed for interconnection of T-Carrier equipment.
Estándares
Internacional  Manufacturer specification
Nacional  UL 444
Descripción

Construction

Tinned copper wire insulated with cellular polyethylene (non-plenum) or cellular FEP(plenum),  2 through 4 twisted pairs are individually shielded with an aluminum/polyester tape, foil facing out,  which is in contact with a stranded tinned copper drain wire.  The cable core is wrapped by a polyester tape and jacketed with a flame-retardant PVC (non-plenum) or fluoropolymer (plenum) jacket.

Standards

  • North American:  ANSI/T1/102-1987, UL 444 and C22.2 No. 214-02
  • International: EU directive 2002/95/EC (RoHS)

 

Flame Rating

  • Plenum – NFPA 262, CMP
  • Non-Plenum UL 1685, CM
  • UL Listed

 

Applications

  • T1
  • DS-1

 

Features

  • Individually Shielded Pairs
  • General purpose or plenum rated
  • Available in constructions up to 4 pairs
  • Compact size

 

 Benefits

  • Supports T1 interconnection applications
  • Individual pair isolation allows for maximum protection from outside interference 

 TOP
Características
Características de construcción
Color Gris  
Características dimensionales
Length per reel 1000.0ft  
Características de uso
Embalaje Bobina desechable  

 TOP
Búsqueda parametrizada
Número de pares  
Fire safety  
Galga (AWG)  
Solicita
Restaurar
Su selección   4/4
Selecciona todos los artículos Ref. Nexans Nombre Número de pares Fire safety Galga (AWG)
10032390 T1 - Telephone Exchange Cable 2 CM 22
10032052 T1 - Telephone Exchange Cable 2 Plenum Rated 22
10047514 T1 - Telephone Exchange Cable 4 Plenum Rated 22
10032053 T1 - Telephone Exchange Cable 2 Plenum Rated 24
Añade a favoritos

 TOP
Technical Data - Physical

 

CM

CMP

Conductor solid TC

22 AWG

24 AWG 

22 AWG 

24 AWG 

Conductor Diameter (in. nom)

0.025

0.020

0.025

0.020

Insulated Conductor Diameter  (in. nom)

0.063

0.052

0.063

0.050

Drain Wire, Stranded Tinned Copper

22 AWG 

24 AWG 

22 AWG 

24 AWG 

Cable Diameter 2 PR  (in. nom)

0.272

0.270 x .170

0.222

0.200

Cable Diameter 4 PR  (in. nom)

-

0.325

0.324

-

Cable Weight 2 PR (lbs/1000 ft nom.)

35

28

23

19

Cable Weight 4 PR (lbs/1000 ft nom.)

-

40

45

-

Outer Sheath

FR-PVC

FR-PVC

Fluoropolymer

Fluoropolymer

Color

Gray

Gray

Gray

Gray


Technical Data - Electrical

 

CM

CMP

22 AWG 

24 AWG 

22 AWG 

24 AWG 

Conductor DC Resistance 
Ohms/1000 ft. @ 20C

17.2

26.2

17.2

26.2

Mutual Capacitance pf/ft nom.

12.5

14

12.5

12.5

Characteristic Impedance Ohms +,- 10 @ 772 kHz

100

100

100

100

Attenuation dB/1000 ft. max @ 772 kHz

7

7

7

7

Attenuation dB/1000 ft. max @ 1.54 kHz

-

-

8.5

8.5

FEXT dB/1000 ft. min at 1.544 MHz

85

85

85

85

NEXT dB/1000 ft. min at 1.544 MHz

80

80

80

80


Color code

Pair 1

wht

wht/red

Pair 3

wht

wht/blk

Pair 2

wht

wht/grn

Pair 4

wht

wht/blu


 TOP
Información sobre entregas
PLEASE NOTE: In the interest of product improvement, Berk-Tek, a Nexans company may make improvements or changes in the products, the programs or services described at any time without notice. Additionally, the information contained herein may include typographical errors or technical inaccuracies. Changes will be periodically made to address any such issues.