English conectarse Registrarse Catalog Browser Contact Us
Experto global en cableado y en sistemas de cableado

Sobre Nexans

Productos y Soluciones

Servicios al cliente

Trabaje en Nexans

Noticias y prensa

IR

LANmark-6 OSP

Bookmark Imprimir Contactanos
LANmark-6 OSP Berk-Tek’s LANmark-6 OSP (Outside Plant) Standard Category 6 UTP cables are designed for outside applications, either aerial or buried in conduit or duct, where building to building interconnections must be made.
Estándares
Nacional  TIA/EIA-568-B.2
Descripción

Construction: 24 AWG bare copper wire insulated with polyethylene.  Two insulated conductors twisted together to form a pair and four such pairs cabled around a cross filler to form the basic unit which is injected with a water resistant flooding compound and jacketed with UV resistant polyethylene jacket.

 

Standards: North American:  ANSI/TIA/EIA-568-B.2-1 Category 6

 

 

Flame Rating:  Not flame rated 

 

 

Applications: Berk-Tek's LANmark-6 UTP cable is intended for high speed data applications including:

  • IEEE 802.3          1000BASE-T          1 Gb/s
  • TIA/EIA-854          1000BASE-TX       1 Gb/s
  • ATM                     155 Mb/s                 155 Mb/s
  • IEEE 802.3           100BASE-TX        100 Mb/s
  • CDDI                                                 100 Mb/s
  • IEEE 802.3            10BASE-T           10 Mb/s

 

Features

  • Meets the requirements of ANSI/TIA/EIA-568-B.2-1
  • Usable bandwidth up to 250 MHz
  • Fully water blocked

 

 

Benefits

  • Can be used to interconnect buildings or can be run beneath a slab in duct or conduit
  • Simplified structured cabling solution preserving long-term network investment
  • Warranted, trouble-free cabling installation and maintenance
  • Meets NEC requirement for wet locations

 


 TOP
Características
Características de construcción
Tipo de cable 19x0.32  
Color Black  
Características dimensionales
Length per reel 1000.0ft  
Número de pares 4  
Características de uso
Embalaje Bobina desechable  
Campo de aplicación Outdoor  
Categoría Cat. 6  
Fire safety _  

 TOP
Su selección   1/1
Selecciona todos los artículos Ref. Nexans Nombre
10139885 LANmark-6 OSP UTP
Añade a favoritos

 TOP
Technical Data - Physical
LM6 OSP physical 071811

Technical Data - Physical

 

Color Code

 

Pair-1

White/Blue

Blue

Conductor

24 AWG Bare Copper

Pair-2

White/Orange

Orange

Conductor diameter–in. (mm) 

0.021

(0.54)

Pair-3

White/Green

Green

Insulated Conductor Diameter- in. (mm)

0.042

(1.07)

Pair-4

White/Brown

Brown

Cable diameter–in. (mm) 

0.25

(6.4)

 

Nominal cable weight–lb./kft. (kg/km) 

28

(41.3)

Temperature Rating

Max. installation tension–lb. (N) 

25

(110)

Installation 

0°C to +50°C 

Min. bend radius–in. (mm) 

1

(25.4)

Operation 

-40°C to +70°C 


Technical Data - Parametric Measurements

Mutual Capacitance 

4.6 nF/100 m nom. 

DC resistance 

8.16 Ohms/100 m nom. 

Skew 

45 ns/100 m max. 

Pair to ground Unbalance 

330 pF/100 m max. 

Velocity of Propagation 

62% nom. 

The use of gel filling in the cable requires a 5% allowance to propagation delay as specified in TIA/EIA-568-B.2-1

Technical Data - Electrical

FREQ  MHz

RL
(dB) 

IL
(dB/100m) 

PS-NEXT
(dB) 

NEXT
(dB)

ACR
(dB/100m) 

PS-ACR 
(dB/100m) 

ELFEXT 
(dB)

PS-ELFEXT 
(dB)

min. 

max. 

min. 

min. 

min. 

min. 

min. 

min. 

1

20.0

2.0

72.3

74.3

72.3

70.3

67.8

64.8

4

23.0

3.8

63.3

65.3

61.5

59.5

55.8

52.8

10

25.0

6.0

57.3

59.3

53.3

51.3

47.8

44.8

16

25.0

7.6

54.3

56.2

48.7

46.7

43.7

40.7

20

25.0

8.5

52.8

54.8

46.3

44.3

41.8

38.8

31.25

23.6

10.7

49.9

51.9

41.2

39.2

37.9

34.9

62.5

21.5

15.4

45.4

47.4

32.0

30

31.9

28.9

100

20.1

19.8

42.3

44.3

24.5

22.5

27.8

24.8

250

17.3

32.8

36.3

38.3

5.4

3.4

19.8

16.8

 
 

 TOP
Información sobre entregas
PLEASE NOTE: In the interest of product improvement, Berk-Tek, a Nexans company may make improvements or changes in the products, the programs or services described at any time without notice. Additionally, the information contained herein may include typographical errors or technical inaccuracies. Changes will be periodically made to address any such issues.

Nexans © copyright 2001 - 2012   Legal Notice | Contact Us | Site Map