HyperPlus 5e OSP Berk-Tek’s Hyper Plus 5e OSP (Outside Plant) Standard Category 5e UTP cables are designed for outside applications, either aerial or buried in conduit or duct, where building to building interconnections must be made.
Estándares
Nacional  TIA/EIA-568-B.2
Descripción

Construction

24 AWG bare copper wire insulated with polyethylene. Two insulated conductors twisted together to form a pair and four such pairs cabled to form the basic unit which is injected with a water resistant flooding compound and jacketed with UV resistant polyethylene.

 

Standards

  • North American ANSI/TIA/EIA-568-B.2 Category 5e and Category 5, ANSI/ICEA 5-56-434
  • International ISO/IEC 11801 Category 5 , EU Directive 2002/95/EC (RoHS)

 

 

Applications

Berk-Tek's Hyper Plus 5e OSP UTP cable is intended for high speed data applications including:

  • IEEE 802.3          1000BASE-T          1 Gb/s
  • ATM                     155 Mb/s          155 Mb/s
  • IEEE 802.3         100BASE-TX         100 Mb/s
  • CDDI                                           100 Mb/s
  • IEEE 802.3          10BASE-T            10 Mb/s

 

Features

  • Supports most data and voice applications
  • Meets ANSI/ICEA 5-56-434 Standard for Polyolefin Insulated Communications Cables for Outdoor Use
  • ETL Verified to TIA/EIA-568-B.2 Category 5e
  • Fully water blocked 

 

Benefits

  • Can be used to interconnect buildings or can be run beneath a slab in duct or conduit
  • Simplified structured cabling solution preserving long-term network investment
  • Meets NEC requirement for cable in wet locations

 TOP
Características
Características de construcción
Color Black  
Características dimensionales
Length per reel 1000.0ft  
Número de pares 4  
Características de uso
Embalaje Bobina desechable  
Categoría Cat. 5e  

 TOP
Su selección   2/2
Selecciona todos los artículos Ref. Nexans Nombre
10071496 HyperPlus 5e OSP
10071496 HyperPlus 5e OSP
Añade a favoritos

 TOP
Technical Data - Physical

Technical Data - Physical

 

Color Code

 

Pair-1

White

Blue

Conductor

24 AWG BC

Pair-2

White

Orange

Conductor diameter–in. (mm) 

0.02

(0.51)

Pair-3

White

Green

Insulated Conductor Diameter- in. (mm)

0.038

(0.96)

Pair-4

White

Brown

Cable diameter–in. (mm) 

0.207

(5.3)

 

Nominal cable weight–lb./kft. (kg/km) 

20

(30)

Temperature Rating

Max. installation tension–lb. (N) 

25

(110)

Installation 

0°C to +50°C 

Min. bend radius–in. (mm) 

1

(25.4)

Operation 

-20°C to +60°C 


Technical Data - Parametric Measurements

Mutual Capacitance 

5.6 nF/100 m max. 

DC resistance 

9.38 Ohms/100 m max. 

Skew 

25 ns/100 m max. 

Pair to ground Unbalance 

330 pF/100 m max. 

Velocity of Propagation 

72% nom. 

Input Impedance 

100 ± 15% 1-100 MHz 

DC Resistance Unbalance:

5% max.


Technical Data - Electrical

FREQ
MHz 

SRL
(dB) 

RL
(dB)  

IL
(dB/100m)  

PS-NEXT 
(dB)

NEXT
(dB) 

ACR
(dB/100m)  

PS-ACR
(dB/100m) 

ELFEXT
(dB)  

PS-ELFEXT
(dB) 

min. 

min. 

max. 

min. 

min. 

min. 

min. 

min. 

min. 

1

25.0

20.0

2.0

62.3

66.3

64.3

60.3

63.8

60.8

4

25.0

23.0

4.1

53.3

57.3

53.2

49.2

51.8

48.8

10

25.0

25.0

6.5

47.3

51.3

44.8

40.8

43.8

40.8

16

25.0

25.0

8.2

44.2

48.3

40.1

36

39.7

36.7

20

25.0

25.0

9.3

42.8

46.8

37.5

33.5

37.8

34.8

31.25

23.6

23.6

11.7

39.9

43.9

32.2

28.2

33.9

30.9

62.5

21.5

21.5

17.0

35.4

39.4

22.4

18.4

27.9

24.9

100

20.1

20.1

22.0

32.3

36.3

14.3

10.3

23.8

20.8


 TOP
Información sobre entregas
PLEASE NOTE: In the interest of product improvement, Berk-Tek, a Nexans company may make improvements or changes in the products, the programs or services described at any time without notice. Additionally, the information contained herein may include typographical errors or technical inaccuracies. Changes will be periodically made to address any such issues.