We have designed the cables H07BB-F for uses in environment with a very low ambient temperature.
Maximum temperature on conductor in normal use + 60°C and under short circuit condition 200°C.
Can be used in open air. If buried it must have an extra mechanical protection (tube, gutter).
Conductors laid up
assembled conductor. Filler and reinforcement tape in some case.
Tractive force
Maxi 15N/mm² in relation to the section of core or 1000 N max for the full cable.
(metric marking is possible for special fabrications)
Max continuous operating conductor temperature in normal use :
+60°C ( in every case of mobile installation)
+85°C ( fixed protected installation )
+200°C ( in short circuit )
Permissible current rating is measured for an ambient temperature of 30°C and a maximum operating and conductor temperature of 85°C . For other temperature please refer to correction factors .
Number of cores
HD 308 S2 since january 2004
G (earth core)
X (without earth core)
1
Black (preferential)
2
Blue + Brown
3*
Green - Yellow + Blue + Brown
Brown + Black + Grey
3**
Blue + Brown + Black
4
Green - Yellow + Brown + Black + Grey
Blue + Brown + Black + Grey
5
Green - Yellow + Blue + Brown + Black + Grey
Blue + Brown + Black + Grey + Black
> 5
White printed numbers + 1 Green - Yellow
White printed numbers
* For the cables without Green/Yellow with a cross-section >4mm²