español Login Get Registered Catalog Browser Contact Us
Global expert in cables and cabling system

About Nexans

Products and Solutions

Customer Service

Work at Nexans

News and Press

Go

RHEYHALON (N)MHXAFOE-FR 0.6/1 (1.2)kV

Send link to this page print Your Nexans contact on this page
RHEYHALON (N)MHXAFOE-FR 0.6/1 (1.2)kV EN 50264-3-1 addtional EN 50200
Halogenfree single core cable with circiut integrity (15 min)
0,6/1 kV
Standards
International  EN 50200; EN 50264-3-1
National  BS 6853; DIN 5510-1; DIN VDE 0295
Description


Applications

Flexible cable with emergency operating features for inner wiring in railway vehicles (locomotives, trains, trolley busses), switching stations and control panels.
Current carrying capacity acc. to EN 50343 as well as VDE 0298 part 4. Serves request acc. to EN 45545-1.
Circuit integrity acc. to EN 50200 (15 minutes) resp. EN 50362.

 

Design

1. Conductor

Flexible stranded tinned copper, class 5 acc. to DIN VDE 0295 / IEC 60228
/ HD 383.

2. Minerally conductor taping

3. Insulation

Double layer insolation type EI110/EI109 (EM104) acc. to EN 50264-1,
oil, diesel-oil, ozone and uv resistant.

 

Cable marking

e.g.: RHEYHALON (N)MHXAFOE-FR  0,6/1 kV EN 50264-3-1 600V 0,5 M  FA-Nr. ...
 

Core colours

Black (BK); green/yellow (GNYE); other colours on request


 

Additional standards

DIN 5510 part 1:, flame protection class 1, 2, 3 and 4
BS 6853 (on request)


 TOP
Characteristics
Construction characteristics
Halogen free IEC 60754-1  
Usage characteristics
Operating temperature, range -40 .. 90°C  
Gases corrosivity No acc. to EN 50267-2-2  
Gases toxicity innocuous EN 50305-9.2  
Flame retardant EN 60332-1-2 & EN 60332-3-24 & EN 60332-3-25  
Smoke density EN/IEC 61034-2  
Standard EN  
Bending factor when installed 5(xD)  
Bending factor when laying 10(xD)  
Oil resistance Yes  
Ozone resistance Yes  
U.V resistance Yes  

 TOP
Your selection
Colour  
Conductor cross-section  mm²
Minimum outer diameter  mm
Maximum outer diameter  mm
Fire load  kWh/m
Approximate weight  kg/km
Apply
Reset
Results   2/2
Select all Items Nexans ref. Colour Cross section (mm²) Min. outer diam. (mm) Max. outer diam. (mm) Fire load (kWh/m) Approx. weight (kg/km)
79471107 Black 1.5 3.4 3.8 0.04 24
79471166 Black 16 7.1 7.7 0.12 170
Add to favorites

 TOP
Electrical properties

Max. operating voltage (d.c.)                                                         

Vo =500 or 1500V 


Max. operating temperature at conductor

Conductor at normal operation

≤ 90 °C/250.000 h

 

≤ 120 °C/20.000 h

Overload 

≤ 160 °C / 50 h

Conductor under short-circuit conditions (tinned)

≤ 200 °C


 TOP
Selling delivery information
  • Other cross-sections on request.

  • Special conditions relating temperature and bending radii (e.g. by compelled guidance into cluthes, wagontransition and boogies) on request.


  • Nexans © copyright 2001 - 2012   Legal Notice | Contact Us | Site Map