WINDLINK® UL/CSA EPR/CPE 1000V 90°C

Send link to this page print Your Nexans contact on this page
WINDLINK® UL/CSA EPR/CPE 1000V 90°C

Appliance Wiring Material UL 758 standard certified
1000 V – 90°C
Style 3850 for single cores & Style 4558 for multi-cores
UL/CSA 22.2
AWM class I, II, or I / II , Group A,B, or A/B

UL CSA
Description

Application

This cable is specially designed for Wind Turbines

The quality of material used for insulation and sheathing and high quality copper conductors make the cables both flexible, durable, resistant to torsion and to high temperatures. Nexans offers more than a decade of experience in the wind energy market. Our expertise makes WINDLINK® cables highly recommended for wind turbines.

 

Main characteristics

  • Frequent torsion: Excellent torsion behavior
  • Industrial cables resistant to high temperatures
  • Heavy duty
  • Temperature on core: 90°C in normal use; 250°C in short circuit
  • Water resistance: AD2, AD6
  • Corrosive and polluting substances resistance: AF3
  • Outdoor use : temporary and permanent
  • Impact resistance: AG2
  • Oil resistant ASTM/IRM 902
  •  UV resistant for external application
  • Ozone resistant
  • Flame retardant (IEC/EN 60332-1)

 

Design 

1. Conductor :
Annealed plain copper-  Optional tape
Flexible (fine wire class 5 of IEC/EN 60228)

2. Insulation :
Special thermoset EPR for high temperature
Optional tape on insulation or assembling

3. Sheath:
High mechanical performance , oil resistant
Ozone resistant, ref HD 22.1, black colour
Special thermoset CPE improved for low temperature behaviour (-40°C)
 


 TOP
Characteristics
Construction characteristics
Conductor material Plain annealed copper  
Electrical characteristics
Rated Voltage Uo/U (Um) 1000 V  
Mechanical characteristics
Torsion test max. +/- 4 turns for 10 meters max:150° per meter  
Mechanical resistance to impacts Good  
Tensile strength 15N/mm2  
Usage characteristics
Max. conductor temperature in service 90°C  
Short-circuit max. conductor temperature 250°C  
Minimum operating temperature -40°C  
Ambient installation temperature, range -40 .. 80°C  
Ambient dynamic operating temperature, range -40 .. 50°C  
Operating temperature, range -40 .. 90°C  
Ambient static operating temperature, range -40 .. 50°C  
Oil resistance Good  
U.V resistance Very good  
Watertightness AD2 to AD6  

 TOP
Your selection
Conductor cross-section  mm²
Number of cores  
Outer diameter acc Windturbines needs Min Max  mm
Apply
Reset
Results   4/4
Select all Items Nexans ref. Cross section (mm²) Nb. of cores Outer diam. Wind Min Max (mm)
1 x 35 7.6 1 15.5 .. 18.5
1 x 185 18 1 28.0 .. 32.0
4 G 1.5 1.5 4 11.7 .. 14.0
4 G 35 7.6 4 32.5 .. 40.0
Add to favorites

 TOP
Complementary technical for Windlink®

Usage characteristics:

Mechanical stress :

(on the whole cable, per mm² of a cross section of plain copper core)

  • In normal use : 15 N/mm²

 

Mechanical characteristics:

Bending Radius

Mobile use = 6 x External diameter.
Static use = 3 x External diameter , if the external diameter < 12mm, 4 x if the external diameter >12 mm.

 

Electrical characteristics:

Permissible current rating: 

  • Permanent temperature of operation on the core 90°C
  • Ambient temperature for an outdoor installation  30°C

 

Correction factors according for other ambient temperature : according to IEC 60364.5.523 table 52.D1 or DIN VDE 0298-4 Table 15

Ambient
temperature (°C)
10 15 20 25 30 35 40 45 50 55 60 65 70 75
factors  1.17 1.13 1.09 1.04 1 0.96 0.91 0.87 0.82 0.76 0.69 0.62 0.54 0.45

The Voltage drop has been determined with Cos φ= 0.8

 

 Short circuit : constant K=139 Amps for 1 second, acc.to IEC 60949 ( short circuit temperature +250°C and conductor temperature +90°C)

 

 


 TOP
UL/CSA EPR/CPE 1000V

Other properties

Standard tests according to UL 758 standard style 3850 (single core), style 4558 (multi-core cables)
UV resistant sheath black sheath is UV resistant for external application
Oil resistant sheath good in oils, greases, gear box oil, etc
  • ASTM/IRM 902
24h at 100°C
  • Gear box oil as Tribol 1710/320 or equiv oil.
72h at 40°C or 24 h at 100°C
  • Hydraulic oil Mobil DTE 13m or equiv oil.
72h at 40°C or 24 h at 100°C

 TOP
Selling delivery information

Marking

WINDLINK® NEXANS 213
Nb cores X (or G) S
X = without G/Y
G = with G/Y
S = cross section (mm2)
+ "UL/CSA" marking
Week + year manufacturing
meter marking

 

Insulated Cores identification

• 1 core = Black (preferential)
• 2 cores = Brown + Blue
• 3 cores = Green/Yellow +Blue + Brown (G)
Brown + Black + Grey (X S>4mm²)
Blue + Brown + Black (X S 1.5 & 2.5 mm²)
• 4 cores = Green/Yellow + Brown + Black + Grey (G)
Blue + Brown + Black + Grey (X S 1.5 & 2.5 mm²)