MPRX® 0.6/1 (1.2 ) kV

Send link to this page print Your Nexans contact on this page
MPRX®   0.6/1  (1.2 )  kV Halogen Free Power Cables without screen 0.6/1 kV
Standards
International  IEC 60092-350; IEC 60092-351; IEC 60092-353; IEC 60092-359; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034
Description

Applications

For fixed installation on ships and offshore-units in all locations below the upper metallic deck.
A more specific design (e.g. screening) is necessary for installations in radio stations or above the upper metallic deck.
The cables meet the flame test requirements for bunched cables acc. to IEC 60332-3-22 and IEEE 45-18.13 and perform to the SOLAS requirements. All cable materials are free of halogens. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, these cables are especially suitable for the installation on passenger ships.

 

Design

  1. Conductor: Stranded bare copper class 2
  2. Insulation: XLPE (cross linked polyethylene)
  3. Outer sheath (Separator/filler if necessary):Polyolefin, colour: black

 

Marking

e.g.: l NEXANS l MPRX 3x1,5 0,6/1kV 90°C IEC 60092-353 IEC 60332-3-22 YEAR *CE* + Metric Marking

 

Core Identification

In line with DIN VDE 0293-308
1 core: black
2 cores: blue/brown
3 cores: brown/black/grey
4 cores: blue/brown/black/grey
5 to 24 cores cables: all cores white coloured, printed with black numbers, starting in center with 1.
Cables with 3 cores and more also with green-yellow core (has to be stated in order).


 TOP
Characteristics
Construction characteristics
Conductor material Bare copper  
Conductor flexibility Stranded class 2  
Halogen free IEC 60754-1  
Insulation Polyester tape separator  
Protection Filler (optional)  
Outer sheath Tinned copper  
Sheath colour Black  
Electrical characteristics
Rated Voltage Uo/U (Um) 0.6/1 kV  
Maximum operating voltage 1.2kV  
Test voltage 3500V  
Usage characteristics
Max. conductor temperature in service 90°C  
Short-circuit max. conductor temperature 250°C  
Minimum installation temperature -10°C  
Minimum operating temperature -35°C  
Flame retardant IEC 60332-3 Cat. A  
Smoke density IEC 61034  
Gases corrosivity IEC 60754-2  
Gases toxicity No toxicity to IEC 60754-1  
Standard IEC  

 TOP
Your selection
Number of cores  
Conductor cross-section  mm²
Minimum outer diameter  mm
Maximum outer diameter  mm
Approximate weight  kg/km
Apply
Reset
Results   53/53
Select all Items Nexans ref. Name Nb. of cores Cross section (mm²) Min. outer diam. (mm) Max. outer diam. (mm)
25403844 MPRX® 1 x 10 mm² 1 10 7.0 9.5
25403025 MPRX® 1 x 120 mm² 1 120 18.0 21.0
25403026 MPRX® 1 x 150 mm² 1 150 20.0 23.5
25403845 MPRX® 1 x 16 mm² 1 16 8.0 10.5
25403027 MPRX® 1 x 185 mm² 1 185 22.0 25.5
25403125 MPRX® 1 x 240 mm² 1 240 25.0 28.5
25403846 MPRX® 1 x 25 mm² 1 25 9.5 12.0
25403126 MPRX® 1 x 300 mm² 1 300 27.5 31.5
25403847 MPRX® 1 x 35 mm² 1 35 10.5 13.0
25403842 MPRX® 1 x 4 mm² 1 4 5.5 8.0
25403062 MPRX® 1 x 50 mm² 1 50 12.0 14.5
25403843 MPRX® 1 x 6 mm² 1 6 6.0 8.5
25403848 MPRX® 1 x 70 mm² 1 70 14.0 16.5
25403061 MPRX® 1 x 95 mm² 1 95 16.0 19.0
25403141 MPRX® 10 x 1.5 mm² 10 1.5 13.5 16.0
25403142 MPRX® 12 x 1.5 mm² 12 1.5 14.0 17.0
25403143 MPRX® 14 x 1.5 mm² 14 1.5 14.5 17.5
25403144 MPRX® 16 x 1.5 mm² 16 1.5 15.5 18.5
25403154 MPRX® 19 x 1.5 mm² 19 1.5 16.5 19.5
25403063 MPRX® 2 x 1.5 mm² 2 1.5 7.0 9.5
25403851 MPRX® 2 x 10 mm² 2 10 12.5 15.0
25403852 MPRX® 2 x 16 mm² 2 16 14.5 17.0
25403075 MPRX® 2 x 2.5 mm² 2 2.5 8.0 10.5
25403067 MPRX® 2 x 25 mm² 2 25 18.0 20.5
25403849 MPRX® 2 x 4 mm² 2 4 9.0 11.5
25403850 MPRX® 2 x 6 mm² 2 6 10.0 12.5
25403145 MPRX® 24 x 1.5 mm² 24 1.5 19.5 22.5
25403069 MPRX® 3 x 1.5 mm² 3 1.5 8.0 10.5
25403097 MPRX® 3 x 10 mm² 3 10 13.0 15.5
25403120 MPRX® 3 x 120 mm² 3 120 33.5 37.5
25403100 MPRX® 3 x 16 mm² 3 16 15.5 18.0
25403076 MPRX® 3 x 2.5 mm² 3 2.5 9.0 11.5
25403104 MPRX® 3 x 25 mm² 3 25 19.0 21.5
25403107 MPRX® 3 x 35 mm² 3 35 20.5 23.5
25403083 MPRX® 3 x 4 mm² 3 4 10.0 12.5
25403109 MPRX® 3 x 50 mm² 3 50 24.0 27.0
25403030 MPRX® 3 x 6 mm² 3 6 11.0 13.5
25403114 MPRX® 3 x 70 mm² 3 70 26.5 29.5
25403117 MPRX® 3 x 95 mm² 3 95 30.5 34.0
25403070 MPRX® 4 x 1.5 mm² 4 1.5 8.5 11.0
25403098 MPRX® 4 x 10 mm² 4 10 14.5 17.0
25403101 MPRX® 4 x 16 mm² 4 16 17.0 19.5
25403077 MPRX® 4 x 2.5 mm² 4 2.5 10.0 12.5
25403105 MPRX® 4 x 25 mm² 4 25 21.0 24.0
25403108 MPRX® 4 x 35 mm² 4 35 23.0 26.0
25403084 MPRX® 4 x 4 mm² 4 4 11.0 13.5
25403111 MPRX® 4 x 50 mm² 4 50 27.0 30.0
25403091 MPRX® 4 x 6 mm² 4 6 12.0 14.5
25403115 MPRX® 4 x 70 mm² 4 70 31.0 34.5
25403118 MPRX® 4 x 95 mm² 4 95 35.5 39.5
25403054 MPRX® 5 x 1.5 mm² 5 1.5 9.5 12.0
25403078 MPRX® 5 x 2.5 mm² 5 2.5 10.5 13.0
25403055 MPRX® 7 x 1.5 mm² 7 1.5 10.5 13.0
Add to favorites

 TOP
Additional Cable Characteristics

Minimum internal bending radius

 

- for overall diameter of cables ≤ 25 mm

4 x cable diameter

- for overall diameter of cables > 25 mm

6 x cable diameter

 

 

Current ratings for continuous operation and further hints for cable installation

 

are according to IEC 60092-352

 


Approval

Type Approval Certificates   

 

• American Bureau of Shipping

 

• Bureau Veritas

 

• Det Norske Veritas 

 

• Germanischer Lloyd

 

• Lloyd´s Register of Shipping

 

• Registro Italiano Navale (pending)

 

• Russian Maritime Register of Shipping

 


 TOP
MPRX®   0.6/1  (1.2 )  kV   ABS Certificate valid until 04.01.2011 (119 kB)
MPRX®   0.6/1  (1.2 )  kV   DNV Certificate valid until 30.06.2009 (210 kB)
MPRX®   0.6/1  (1.2 )  kV   GL Certificate valid until 22.03.2011 (20 kB)
MPRX®   0.6/1  (1.2 )  kV   RMRS Certificate valid until 26.04.2011 (93 kB)
MPRX®   0.6/1  (1.2 )  kV   BV Certificate valid until 26.05.2013 (611 kB)

Nexans © copyright 2001 - 2012   Legal Notice | Contact Us | Site Map