RG-11 CATV Quad Shield

Send link to this page print Your Nexans contact on this page
Berk-Tek’s CATV grade, RG-11 Quad Shield Coaxial Cables are designed to support a variety of CATV Hook-up and Trunk applications.
Standards
International  Manufacturer specification
Description

Standards/Flame Rating

  • Non-plenum-UL 1581 CATV, CM,
  • UL 1666 CATVR, CMR
  • Plenum-NFPA 262, CATVP, CMP

 

Features

  • High Quality Low Emission Cables
  • Available in Plenum, Riser and General Purpose rated versions
  • Flexible design 

 

Benefits

  • Clear Broadcasts, minimal interference
  • Easy to terminate
  • Universally accepted design

 TOP
Characteristics
Dimensional characteristics
Length per reel 1000.0ft  
Usage characteristics
Packaging Reel  
Field of application Indoor  

 TOP
Your selection
Sheath colour  
Fire safety  
Apply
Reset
Results   5/5
Select all Items Nexans ref. Name Sheath colour Fire safety
10061906 RG-11 Quad Shield CM Rated Black CM
10061907 RG-11 Quad Shield CM Rated White CM
10061910 RG-11 Quad Shield Plenum Rated Black Plenum Rated
10061909 RG-11 Quad Shield Plenum Rated White Plenum Rated
10065782 RG-11 Quad Shield Riser Rated Black Riser Rated
Add to favorites

 TOP
Technical Data - Physical

Minimum Bend Radius

1.5 in. (38.1 mm)

Cable Temperature Rating 

CMP -10-125°C

CM 0-75°C


Technical Data - Dimensions

 

CM, CMR

CMP

 

in. 

mm 

in. 

mm 

Inner Conductor 

0.0641

1.63

0.0641

1.63

Dielectric 

0.28

7.11

0.28

7.11

1st Outer Conductor (100%) 

0.288

7.32

0.288

7.32

2nd Outer Conductor (60%) 

0.312

7.92

0.312

7.92

3rd Outer Conductor (100%) 

0.316

8.03

0.316

8.03

4th Outer Conductor (40%) 

0.341

8.66

0.341

8.66

Jacket 

0.407

10.34

0.372

9.45


Technical Data - Electrical

FREQUENCY 
MHz 

CM, CMR 

CMP 

Attenuation
dB/100 ft. (nom.) 

Attenuation
dB/100 ft. (max.) 

Attenuation
dB/100 ft. (nom.) 

Attenuation
dB/100 ft. (max.)  

1 MHz 

0.17

0.19

0.14

0.15

10 MHz 

0.43

0.46

0.46

0.47

50 MHz 

0.8

0.84

1.08

1.09

100 MHz 

1.19

1.26

1.53

1.59

200 MHz 

1.68

1.79

2.16

2.35

400 MHz 

2.5

2.53

3.2

3.52

700 MHz 

3.38

3.44

4.44

4.94

900 MHz 

3.83

3.99

5.37

5.79

1000 MHz 

4.12

4.23

5.78

6.19

1200 MHz 

4.51

4.71

6.33

6.78

1450 MHz 

4.96

5.29

6.96

7.45

1800 MHz 

5.53

6.04

7.76

8.3

2000 MHz 

5.83

6.36

8.17

8.75

2200 MHz 

6.11

6.68

8.57

9.18


Technical Data - Electrical

 

CM, CMR 

CMP 

Impedance, Ohms 

75± 3 

75± 3 

Velocity of Propagation, % 

85

82

Capacitance, Nominal 

16.2 pF/ft 

53.2 pF/m 

16.0 pF/ft 

52.4 pF/m 

DC Resistance 

Ohms/kft 

Ohms/kft 

Ohms/kft 

Ohms/kft 

Inner Conductor 

12.1

40

12

40

Outer Conductor

3.55

12

3.16

10

Loop 

15.7

52

15.3

50

SRL

5-1000 MHz 

20 dB min. 

5-1000 MHz 

20 dB min. 

1000-2200 MHz 

15 dB min. 

1000-2200 MHz 

15 dB min. 


 TOP
Selling delivery information
PLEASE NOTE: In the interest of product improvement, Berk-Tek, a Nexans company may make improvements or changes in the products, the programs or services described at any time without notice. Additionally, the information contained herein may include typographical errors or technical inaccuracies. Changes will be periodically made to address any such issues.