Premises Distribution Plenum Rated Optical Cable

Send link to this page print Your Nexans contact on this page
Premises Distribution Plenum Rated Optical Cable Berk-Tek’s tight buffered, fiber optic cable is designed for installation in plenum, riser and horizontal environments and interbuilding backbone structures.
Standards
International  EN 50173; ISO/IEC 11801
National  ANSI/ICEA S-83-596; ANSI/TIA-568-C.3; Telcordia GR-409
Description

Construction

  • 900 µm buffered fibers surrounded by aramid yarns
  • Sheathed using a special, state-of-the-art polymer material
  • All dielectric
  • OFNP Rated
  • Aluminum and Steel interlock armor available

 

Outdoor Considerations

Black jacketed and water-blocked versions of this plenum cable is available upon request for outdoor installations.  Outdoor versions feature UV and fungus resistant jacketing.

 

Applications

Berk-Tek's tight buffered plenum distribution cable is intended for all high speed data applications including:

 

  • 10BASE-FL
  • 100BASE-SX/100BASE-FX
  • ATM 155/ATM 622
  • 1000BASE-SX/1000BASE-LX
  • Fibre Channel 1.062/2.125
  • 10GBASE-SR/SW
  • 10GBASE-LX4
  • 40/100 GbE

 

Features

  • Single-mode, multimode, GIGAliteTM and hybrid designs available
  • Available with new bend-optimized single-mode fibers
  • High tensile strength, crush resistant
  • Flexible, small diameter, 900 µm tight buffered construction
  • Six to 144 count fiber construction plenum designs ideal for horizontal and backbone and installations and along plenums 
  • Also available in low smoke zero halogen riser rated design
  • Configurations available suitable for indoor/outdoor installations in conduit, below the frost line 

 

Benefits

  • Cost-saving design, easy to install and terminate
  • Provides for greater pulling distances thus reducing installation time
  • Assurance that cables will meet required specifications for communication networking applications
  • Broad design selection allows for mix and match of fiber components to specific networking applications

 TOP
Characteristics
Construction characteristics
Type of cable Tight Buffered (TB)  
Usage characteristics
RoHS conform Yes  
Operating temperature, range -20 .. 75°C  
Ambient installation temperature, range 0 .. 75°C  
Storage temperature, range -40 .. 85°C  

 TOP
Your selection
Optical performance  
Number of optical fibres  
Outer sheath  
Apply
Reset
Results   68/68
Select all Items Nexans ref. Name
PDP012CB3510/25 12 x OM1 Premise Distribution Plenum Cable
PDP012GB3510/25 12 x OM1+ Premise Distribution Plenum Cable
PDP012ZB3515/55 12 x OM2 Premise Distribution Plenum Cable
PDP012LB3010/75 12 x OM2+ Premise Distribution Plenum Cable
PDP012EB3010/25 12 x OM3 Premise Distribution Plenum Cable
PDP012FB3010/F5 12 x OM4 Premise Distribution Plenum Cable
PDP012XB3010/X5 12 x OM4+ Premise Distribution Plenum Cable
PDP012AB0707 12 x OS2 Premise Distribution Plenum Cable
PDP12B144CB3510/25 144 x OM1 Premise Distribution Plenum Cable
PDP12B144GB3510/25 144 x OM1+ Premise Distribution Plenum Cable
PDP12B144ZB3515/55 144 x OM2 Premise Distribution Plenum Cable
PDP12B144LB3010/75 144 x OM2+ Premise Distribution Plenum Cable
PDP12B144EB3010/25 144 x OM3 Premise Distribution Plenum Cable
PDP12B144FB3010/F5 144 x OM4 Premise Distribution Plenum Cable
PDP12B144XB3010/X5 144 x OM4+ Premise Distribution Plenum Cable
PDP12B144AB0707 144 x OS2 Premise Distribution Plenum Cable
PDP018CB3510/25 18 x OM1 Premise Distribution Plenum Cable
PDP018GB3510/25 18 x OM1+ Premise Distribution Plenum Cable
PDP018ZB3515/55 18 x OM2 Premise Distribution Plenum Cable
PDP018LB3010/75 18 x OM2+ Premise Distribution Plenum Cable
PDP018EB3010/25 18 x OM3 Premise Distribution Plenum Cable
PDP018FB3010/F5 18 x OM4 Premise Distribution Plenum Cable
PDP018XB3010/X5 18 x OM4+ Premise Distribution Plenum Cable
PDP018AB0707 18 x OS2 Premise Distribution Plenum Cable
PDP024CB3510/25 24 x OM1 Premise Distribution Plenum Cable
PDP12B024CB3510/25 24 x OM1 Premise Distribution Plenum Cable
PDP024GB3510/25 24 x OM1+ Premise Distribution Plenum Cable
PDP12B024GB3510/25 24 x OM1+ Premise Distribution Plenum Cable
PDP024ZB3515/55 24 x OM2 Premise Distribution Plenum Cable
PDP12B024ZB3515/55 24 x OM2 Premise Distribution Plenum Cable
PDP024LB3010/75 24 x OM2+ Premise Distribution Plenum Cable
PDP12B024LB3010/75 24 x OM2+ Premise Distribution Plenum Cable
PDP024EB3010/25 24 x OM3 Premise Distribution Plenum Cable
PDP12B024EB3010/25 24 x OM3 Premise Distribution Plenum Cable
PDP024FB3010/F5 24 x OM4 Premise Distribution Plenum Cable
PDP12B024FB3010/F5 24 x OM4 Premise Distribution Plenum Cable
PDP024XB3010/X5 24 x OM4+ Premise Distribution Plenum Cable
PDP12B024XB3010/X5 24 x OM4+ Premise Distribution Plenum Cable
PDP024AB0707 24 x OS2 Premise Distribution Plenum Cable
PDP12B024AB0707 24 x OS2 Premise Distribution Plenum Cable
PDP12B048CB3510/25 48 x OM1 Premise Distribution Plenum Cable
PDP12B048GB3510/25 48 x OM1+ Premise Distribution Plenum Cable
PDP12B048ZB3515/55 48 x OM2 Premise Distribution Plenum Cable
PDP12B048LB3010/75 48 x OM2+ Premise Distribution Plenum Cable
PDP12B048EB3010/25 48 x OM3 Premise Distribution Plenum Cable
PDP12B048FB3010/F5 48 x OM4 Premise Distribution Plenum Cable
PDP12B048XB3010/X5 48 x OM4+ Premise Distribution Plenum Cable
PDP12B048AB0707 48 x OS2 Premise Distribution Plenum Cable
PDP006CB3510/25 6 x OM1 Premise Distribution Plenum Cable
PDP006GB3510/25 6 x OM1+ Premise Distribution Plenum Cable
PDP006ZB3515/55 6 x OM2 Premise Distribution Plenum Cable
PDP006LB3010/75 6 x OM2+ Premise Distribution Plenum Cable
PDP006EB3010/25 6 x OM3 Premise Distribution Plenum Cable
PDP006FB3010/F5 6 x OM4 Premise Distribution Plenum Cable
PDP006XB3010/X5 6 x OM4+ Premise Distribution Plenum Cable
PDP006AB0707 6 x OS2 Premise Distribution Plenum Cable
PDP12B072CB3510/25 72 x OM1 Premise Distribution Plenum Cable
PDP12B072GB3510/25 72 x OM1+ Premise Distribution Plenum Cable
PDP12B072ZB3515/55 72 x OM2 Premise Distribution Plenum Cable
PDP12B072LB3010/75 72 x OM2+ Premise Distribution Plenum Cable
PDP12B072EB3010/25 72 x OM3 Premise Distribution Plenum Cable
PDP12B072FB3010/F5 72 x OM4 Premise Distribution Plenum Cable
PDP12B072XB3010/X5 72 x OM4+ Premise Distribution Plenum Cable
PDP12B072AB0707 72 x OS2 Premise Distribution Plenum Cable
PDP024-012EB3010/25-012AB0707 Hybrid 12xOS2 & 12xOM3 Premise Distribution Plenum Cable
PDP12B036-024EB3010/25-012AB0707 Hybrid 12xOS2 & 24xOM3 Premise Distribution Plenum Cable
PDP12B048-024EB3010/25-024AB0707 Hybrid 24xOS2 & 24xOM3 Premise Distribution Plenum Cable
PDP012-006EB3010/25-006AB0707 Hybrid 6xOS2 & 6xOM3 Premise Distribution Plenum Cable
Add to favorites

 TOP
Sheath Colors

Fiber Type

ISO-TIA
Standard

Effective Modal
BW @ 850 nm

Overfilled Launch
BW @ 850 nm

Attenuation
@ 850 nm

Attenuation
@ 1300 nm

Attenuation
@ 1550 nm

Sheath Color

AB

OS2

NS

NS

NS

0.7 dB/km

0.7 dB/km

Yellow

CB

OM1

200 MHz-km

200 MHz-km

3.5 dB/km

1.0 dB/km

NS

Orange

GB

OM1+

500 MHz-km

350 MHz-km

3.5 dB/km

1.0 dB/km

NS

Orange

ZB

OM2

500 MHz-km

500 MHz-km

3.5 dB/km

1.5 dB/km

NS

Orange

LB

OM2+

950 MHz-km

700 MHz-km

3.0 dB/km

1.0 dB/km

NS

Orange

EB

OM3

2000 MHz-km

1500 MHz-km

3.0 dB/km

1.0 dB/km

NS

Aqua

FB

OM4

4700 MHz-km

3500 MHz-km

3.0 dB/km

1.0 dB/km

NS

Aqua

XB

OM4+

4900 MHz-km

3675 MHz-km

3.0 dB/km

1.0 dB/km

NS

Aqua

NS = Not Specified


 TOP
Manufacturing Release

IMPORTANT NOTICE: This product specification is provided for informational purposes only in order to illustrate typical product constructions, applications and/or methods of installation. Because conditions of actual installation and use are unique and will vary, Berk-Tek makes no representation or warranty as to the reliability, accuracy or completeness of this data, even if Berk-Tek is aware of the product's intended use or purpose. Furthermore, this data does not constitute, nor should it be regarded or relied upon, as professional engineering advice. Installation of cable should only be done by qualified personnel and in conformance with all safety, electrical and other applicable codes, standards, rules or regulations. Appropriate and correct product selection, installation and use, and compliance with all such codes, standards, rules and regulations, is a customer/end-user responsibility. Product specifications, standards, programs or services are subject to improvement or changes without notice. Berk-Tek accepts no liability for typographical errors, technical inaccuracies, omissions or misuse of the information contained herein. Changes will be periodically made to address any such issues.


 TOP
Premises Distribution Plenum Rated Optical Cable   Fiber Specifications PS0309.revR (35 kB)