About Nexans
Products and Solutions
Customer Service
Work at Nexans
News and Press
This plenum flame rated drop cable design accommodates 1 or 2 tight buffered optical fibers. Berk-Tek's loose tube tight buffered drop cables are available in Multimode, Single-mode, and GIGAlite fibers. Construction Each DryGel water blocked buffer tube contains 1 or 2, 900 µm tight-buffered fibers.
Outdoor Considerations Loose Tube cables are recommended if interbuilding conduit systems are likely to fill with water. Adventum Tight Buffer cables are not suitable for aerial-lashed installations. Plenum flame rating allows for building riser shaft penetration or alongside plenums without having to change cabling. Applications Berk-Tek's Adventum Tight Buffer Drop cables are suitable for all passive and active optical network designs requiring high speed voice, video, and data applications, including (but not limited to):
Features
Benefits
PATENT ISSUED
Berk-Tek, a Nexans Company was recently issued a patent on this unique cable design. (U.S. Patent No. 7,664,354)
Fiber Type
ISO-TIAStandard
Effective ModalBW @ 850 nm
Overfilled LaunchBW @ 850 nm
Attenuation@ 850 nm
Attenuation@ 1300 nm
Attenuation@ 1550 nm
Sheath Color
AB
OS2
NS
0.7 dB/km
Black
CB
OM1
200 MHz-km
3.5 dB/km
1.0 dB/km
GB
OM1+
500 MHz-km
350 MHz-km
ZB
OM2
1.5 dB/km
LB
OM2+
950 MHz-km
700 MHz-km
3.0 dB/km
EB
OM3
2000 MHz-km
1500 MHz-km
FB
OM4
4700 MHz-km
3500 MHz-km
XB
OM4+
4900 MHz-km
3675 MHz-km
NS = Not Specified
NFPA 130
2-Fiber ATP Construction
IMPORTANT NOTICE: This product specification is provided for informational purposes only in order to illustrate typical product constructions, applications and/or methods of installation. Because conditions of actual installation and use are unique and will vary, Berk-Tek makes no representation or warranty as to the reliability, accuracy or completeness of this data, even if Berk-Tek is aware of the product's intended use or purpose. Furthermore, this data does not constitute, nor should it be regarded or relied upon, as professional engineering advice. Installation of cable should only be done by qualified personnel and in conformance with all safety, electrical and other applicable codes, standards, rules or regulations. Appropriate and correct product selection, installation and use, and compliance with all such codes, standards, rules and regulations, is a customer/end-user responsibility. Product specifications, standards, programs or services are subject to improvement or changes without notice. Berk-Tek accepts no liability for typographical errors, technical inaccuracies, omissions or misuse of the information contained herein. Changes will be periodically made to address any such issues.