OL:LANmark-10G Augmented Category 6 Riser

Send link to this page print Your Nexans contact on this page
OL:LANmark-10G Augmented Category 6 Riser LANmark™-10G is a next generation cable that is capable of meeting the demanding requirements for 10 gigabit Ethernet (10GBASE-T). This breakthrough cable technology has been specifically designed to reduce “aliencrosstalk” and its effect on 10GBASE-T networks. Alien crosstalk is the coupling interference that comes from nearby cables or other electrical devices. Alien crosstalk has been defined by IEEE as the dominant noise source that will affect 10GBASE-T performance. With its unique patent pending design, LANmark-10G is the most alien crosstalk resistant cable available.LANmark-10G meets the draft standard requirements for augmented Category 6 as defined in TIA/EIA 568-B.2-10 and is a good choice for supporting applications requiring high bandwidth: such as data centers, serverfarms, storage area networks, and campus backbones.
Standards
National  TIA/EIA-568-B.2-1
Description

Construction

23 AWG bare copper wire insulated with polyethylene. Two insulated conductors twisted together to form a pair and four such pairs cabled to form the basic unit, spirally wound with a spacing filament and then jacketed with flame-retardant PVC.

 

Standards

  • North American ANSI/TIA/EIA-568-B.2-10
  • Draft Augmented Category 6

 

Flame Rating

  • Non-Plenum-UL 1666, CMR, IEC 332-1
  • ETL Listed

 

Applications

Berk-Tek's LANmark-10G UTP cable is intended for future and high speed data

and multimedia applications including:

  • IEEE 802.3 10GBASE-T, 1000BASE-T,
  • 100BASE-TX, 10BASE-T, 1000BASE-TX
  • (ANSI/TIA/EIA-854-2001)
  • 155 Mb/s ATM
  • ANSI X3.263 100Mb/s
  • 4/16 Mb/s Token Ring

 

Features

 

  • Alien Crosstalk compliant-ETL Tested
  • Increased usable bandwidth vs. the Category 6 standard
  • Documented balance characteristics (LCL/TCL, EL TCTL)
  • Reduced attenuation (Insertion Loss) 
  • Highest performing UTP cable available
  • RoHS Complient 

 

Benefits

  • Capable of supporting 10GBASE-T networks

  • Provides the bandwidth required for multimedia, broadband video, analog video and other future applications 

  • Balance characteristics improves overall cable performance and reduces cable emission which results in reduced transmission errors 

  • Improved insertion loss allows more signal to reach the receiver resulting in cleaner data and video transmission 

  • State-of-the-art testing allows high frequency characterization of the cable to 500 MHz


 TOP
Characteristics
Construction characteristics
Type of cable 19x0.32  
Dimensional characteristics
Length per reel 1000.0ft  
Number of pairs 4  
Usage characteristics
Packaging Reel  
Field of application Indoor  
Category Cat. 6a  
Fire safety Riser Rated  

 TOP
Your selection
Colour  
Apply
Reset
Results   3/3
Select all Items Nexans ref. Name Colour
10098369 LANmark-10G Riser White
10097591 LANmark-10G Riser Blue
10098370 LANmark-10G Riser Grey
Add to favorites

 TOP
Technical Data - Physical

 

CMR 

Conductor diameter–in. (mm) 

0.023

(0.58)

Cable diameter max.–in. (mm) 

0.35

(8.9)

Nominal cable weight–lb./kft. (kg/km) 

36

(54)

Max. installation tension–lb. (N) 

25

(110)

Min. bend radius–in. (mm) 

1.4

(35.5)


Color Code

Pair-1

White

Blue

Pair-2

White

Orange

Pair-3

White

Brown

Pair-4

White

Green


Parametric Measurements

 

HORIZONTAL 

Mutual Capacitance 

4.4 nF/100 m nom. 

DC resistance max. 

9.38 Ohms/100 m max. 

Skew 

45 ns/100 m max. 

Pair to ground unbalance

330 pF/100 m max. 

Velocity of Propagation

67% nom. 


Temperature Rating

Installation 

0°C to +50°C 

Operation 

-10 to +75°C 


Technical Data - Electrical

FREQ 

RL 

PSANEXT 

PSAELFEXT 

INSERTION LOSS  

NEXT 

PSNEXT 

PSACR 

ELFEXT 

PSELFEXT 

LCL/TCL 

EL TCTL 

(Attenuation)

MHz 

dB min.

dB min.

dB min.

dB max

dB min.

dB min.

dB min.

dB min.

dB min.

dB min.

dB min.

1

20

80

77

2

74.3

72.3

70.3

67.8

64.8

50

35

4

23

74

65

3.7

65.3

63.3

59.6

55.7

52.7

44

23

10

25

70

57

5.9

59.3

57.3

51.4

47.8

44.8

40

15

16

25

68

52.9

7.6

56.3

54.3

46.7

43.7

40.7

38

10.9

20

25

67

51

8.3

54.8

52.8

44.5

41.7

38.7

37

9

31.25

23.6

65.1

47.1

10.4

51.9

49.9

39.5

37.9

34.9

35.1

5.1

62.5

21.5

62

41.1

14.9

47.4

45.4

30.5

31.8

28.8

32

NA 

100

20.1

60

37

19

44.3

42.3

23.3

27.8

24.8

30

NA 

200

18

55.5

31

27.4

39.8

37.8

10.4

21.7

18.7

27

NA 

250

17.3

54

29

31

38.3

36.3

5.3

19.8

16.8

26

NA 

400

15.9

51

25

40

35.3

33.3

NA 

15.7

12.7

24

NA 

500

15.2

49.5

23

45.3

33.8

31.8

NA 

13.8

10.8

23

NA 

IMPORTANT: Berk-Tek performance guarantees are based on swept-frequency testing and apply to all frequencies for the entire specified frequency range and are not limited to the tables of data shown which are presented to demonstrate our guarantees at “representative” frequencies. Values above 500 MHz are provided for engineering information. Other jacket colors available.

 TOP
Selling delivery information
PLEASE NOTE: In the interest of product improvement, Berk-Tek, a Nexans company may make improvements or changes in the products, the programs or services described at any time without notice. Additionally, the information contained herein may include typographical errors or technical inaccuracies. Changes will be periodically made to address any such issues.