español Login Get Registered Catalog Browser Contact Us
Global expert in cables and cabling system

About Nexans

Products and Solutions

Customer Service

Work at Nexans

News and Press

Go

2XS(FL)2YRAA RM 19/33 (36)kV

Send link to this page print Your Nexans contact on this page
2XS(FL)2YRAA RM 19/33 (36)kV International Designation  19/33 (36)kV 3 core Copper XLPE cable, Cu-screen, Al/PE-sheath, Armouring
3 core XLPE-insulated cables with PE sheath and armouring, longitudinally and radially watertight
Standards
International  IEC 60502-2
Description

Stranded copper conductor class 2 according to IEC 60228, semi conducting conductor screen, insulation of cross-linked polyethylene (XLPE), semi conducting insulation screen, semi conducting bedding, copper screen with swellable powder, aluminium tape bonded to PE sheath, 3 core layed up, polypropylene yarn bedding, armouring of galvanized steel, hessian tape and polypropylene yarn serving. 

Application in water, for example internal and external cabling of offshore windparks, power supply of islands, lighthouses and offshore plattforms.

Optionally watertight conductor with sealing compound, lead sheath and Fiber Optics or Control Cables in the interstices available. Other voltages and EPR insulated cables on request.

All medium voltage submarine cables are manufactured on the basis of specifications and can be adapted to the requirements of the customer. Therefore, all technical information are purely for information purposes and the electrical characteristics are calculated for water saturated seabeds and values which are specified in the data sheets. For your specific requirements and laying depths please don't hesitate to contact us.
 


 TOP
Characteristics
Construction characteristics
Number of conductors 3  
Type of conductor Circular compacted stranded  
Screen Copper wire  
Armour type Galvanised round steel wires  
Material used for length water tightness Swelling powder  
Lead free Yes  
Halogen free PE  
Dimensional characteristics
Nominal insulation thickness 8.0mm  
Electrical characteristics
Operating voltage 33kV  
Maximum operating voltage 36kV  
Grounding type Solid bonding  
Load factor 1  
Thermal soil resistivity wet zone 0.7K*m/W  
Usage characteristics
Number of systems 1  
Laying depth, center of system 1000mm  
Ambient ground temperature 15°C  
Bending factor when installed 10(xD)  
Bending factor when laying 15(xD)  
Longitudinal water tightness Yes  
Water proof Radial  
Mechanical Resistance Good mechanical resistance  

 TOP
Your selection
Conductor cross-section  mm²
Screen section  mm²
Nominal outer sheath thickness  mm
Outer Diameter  mm
Approximate weight  kg/m
Maximum pulling force by laying  kN
Permissible current rating when buried  A
Permissible transmission capacity, buried  MVA
Apply
Reset
Results   7/7
Select all Items Nexans ref. Cross section (mm²) Screen section (mm²) Nom. outer sheath thick. (mm) Outer Diameter (mm) Approx. weight (kg/m) Maximum pulling force by laying (kN) Current rating, buried (A) Transm. capacity, buried (MVA)
Make to order product V333x09516 95 16 2.5 100 14.2 81.2 352 20
Make to order product V333x12016 120 16 2.5 104 15.5 85.5 399 23
Make to order product V333x15025 150 25 2.5 108 17.3 88.3 446 25
Make to order product V333x18525 185 25 2.5 111 18.6 91.1 502 28
Make to order product V333x24025 240 25 2.5 116 21 95.4 581 33
Make to order product V333x30025 300 25 2.5 121 23.8 106.8 652 37
Make to order product V333x40035 400 35 2.5 130 28.3 120.8 726 41
Add to favorites