2XS(FL)2YRAA RM 12/20 (24)kV

Send link to this page print Your Nexans contact on this page
2XS(FL)2YRAA RM 12/20 (24)kV International Designation  12/20 (24)kV 3 core Copper XLPE cable, Cu-screen, Al/PE-sheath, Armouring
3 core XLPE-insulated cables with PE sheath and armouring, longitudinally and radially watertight
Standards
International  IEC 60502-2
Description

Stranded copper conductor class 2 according to IEC 60228, semi conducting conductor screen, insulation of cross-linked polyethylene (XLPE), semi conducting insulation screen, semi conducting bedding, copper screen with swellable powder, aluminium tape bonded to PE sheath, 3 core layed up, polypropylene yarn bedding, armouring of galvanized steel, hessian tape and polypropylene yarn serving. 

Application in water, for example internal and external cabling of offshore windparks, power supply of islands, lighthouses and offshore plattforms.

Optionally watertight conductor with sealing compound, lead sheath and Fiber Optics or Control Cables in the interstices available. Other voltages and EPR insulated cables on request.

All medium voltage submarine cables are manufactured on the basis of specifications and can be adapted to the requirements of the customer. Therefore, all technical information are purely for information purposes and the electrical characteristics are calculated for water saturated seabeds and values which are specified in the data sheets. For your specific requirements and laying depths please don't hesitate to contact us.

 

 

 


 TOP
Characteristics
Construction characteristics
Number of conductors 3  
Type of conductor Circular compacted stranded  
Insulating material XLPE  
Screen Copper wire  
Inner sheath HDPE  
Armour type Galvanised round steel wires  
Material used for length water tightness Swelling powder  
Lead free Yes  
Halogen free PE  
Dimensional characteristics
Nominal insulation thickness 5.5mm  
Nominal outer sheath thickness 2.5mm  
Electrical characteristics
Operating voltage 20kV  
Maximum operating voltage 24kV  
Grounding type Solid bonding  
Load factor 1  
Thermal soil resistivity wet zone 1K*m/W  
Usage characteristics
Number of systems 1  
Laying depth, center of system 1000mm  
Ambient ground temperature 20°C  
Bending factor when installed 10(xD)  
Bending factor when laying 15(xD)  
Longitudinal water tightness Yes  
Water proof Radial  
Mechanical Resistance Good mechanical resistance  

 TOP
Your selection
Conductor cross-section  mm²
Screen section  mm²
Conductor diameter  mm
Armour thickness  mm
Outer Diameter  mm
Approximate weight  kg/m
Permissible current rating when buried  A
Permissible transmission capacity, buried  MVA
Apply
Reset
Results   7/7
Select all Items Nexans ref. Cross section (mm²) Screen section (mm²) Conductor diam. (mm) Armour thickness (mm) Outer Diameter (mm) Approx. weight (kg/m) Current rating, buried (A) Transm. capacity, buried (MVA)
Make to order product V203x05016 50 16 8.2 3.15 83 9.3 199 7
Make to order product V203x07016 70 16 9.9 4 87 11.4 243 8
Make to order product V203x09516 95 16 11.5 4 89 12.7 292 10
Make to order product V203x12016 120 16 13.0 4 94 14.1 328 11
Make to order product V203x15025 150 25 14.5 4 97 15.3 364 13
Make to order product V203x18525 185 25 16.1 5 102 18.6 408 14
Make to order product V203x24025 240 25 18.6 5 108 21.1 467 16