FMKHC 150/250 V Halogen Free Communication Cables with screen (armour) 150/250 V
Standards
International  IEC 60092-351; IEC 60092-359; IEC 60092-375; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034
Description

Applications

For fixed installations in communication, radio, control and data processing facilities on ships and offshore units in all locations and on open decks.

The cables meet the flame test requirements for bunched cables acc.to IEC 60332-3 and IEEE 45-18.13, and perform to the SOLAS requirements.

All cables materials are free of halogens. No off-splitting of corrosive gases occurs in case of fire. The off-splitting of toxic gases is minimized. Therefore, these cables are especially suitable for the installation on passenger ships.

 

Design

  1. Conductor: stranded bare copper (7 wires) class 2
  2. Insulation: XLPE (cross linked polyethylene)
  3. Laying up: pair stranding (2 pair cable=quad stranding)
  4. Armouring: separator tape, bare copper braid, separator tape (optional)
  5. Outer sheath: polyolefin, colour: black

 

Marking

e.g.: l NEXANS l FMKHC 250 V 90°C IEC 60092-375 IEC 60332-3-22 HALOGENFREE 19x2x0,75 mm2 + Metric Marking

 

Core Identification

Colour of each pair: black-blue
The cores or each pair are printed with same numbers, starting in center with number 1
2 pair cable (quad):
black / brown / blue / grey


 TOP
Characteristics
Construction characteristics
Conductor material Bare copper  
Conductor flexibility Stranded class 2  
Insulation XLPE (chemical)  
Armour type Bare copper braid  
Outer sheath Polyolefin  
Sheath colour Black  
Halogen free IEC 60754-2  
Electrical characteristics
Test voltage 2kV  
Usage characteristics
Max. conductor temperature in service 90°C  
Short-circuit max. conductor temperature 250°C  
Minimum installation temperature -10°C  
Minimum operating temperature -35°C  
Flame retardant IEC 60332-3 Cat. A  
Smoke density IEC 61034  
Gases corrosivity No IEC 60754-2  
Gases toxicity No toxicity to IEC 60754-1  
Electro magnetic interference resistance Yes  
Standard IEC  

 TOP
Your selection
Number of pairs  
Conductor cross-section  mm²
Minimum outer diameter  mm
Maximum outer diameter  mm
Approximate weight  kg/km
Apply
Reset
Results   8/8
Select all Items Nexans ref. Name nb pairs Cross section (mm²) Min. outer diam. (mm) Max. outer diam. (mm)
25404908 FMKHC 1 x 2 x 0.75 mm² 1 0.75 7.5 8.0
Make to order product 25404918 FMKHC 10 x 2 x 0.75 mm² 10 0.75 18.0 20.6
Make to order product 25404988 FMKHC 14 x 2 x 0.75 mm² 14 0.75 20.0 22.5
Make to order product 25404928 FMKHC 19 x 2 x 0.75 mm² 19 0.75 23.0 25.5
25404958 FMKHC 2 x 2 x 0.75 mm² 2 0.75 8.5 9.8
25404948 FMKHC 24 x 2 x 0.75 mm² 24 0.75 26.0 28.8
25404968 FMKHC 4 x 2 x 0.75 mm² 4 0.75 11.5 14.0
25405215 FMKHC 7 x 2 x 0.75 mm² 7 0.75 14.5 17.0
Add to favorites

 TOP
Additional Cable Characteristics

Minimum internal bending radius

 

- For all diameter

6 x cable diameter

 

 

Conductor resistance

≤ 26.0 Ohm / km

Insulation resistance

> 1100 MOhm x km

Transfer impedance at 10 MHz

 

1- and 2- pair cable

< 80 mOhm / m

4-pair cable

< 60 mOhm / m

7- to 24-pair cable

< 50 mOhm / m

 

 

Current ratings for continuous operation and further hints for cable installation

 

are according to IEC 60092-352

 


Approval

Type Approval Certificates   

 

• American Bureau of Shipping

 

• Bureau Veritas

 

• Det Norske Veritas 

 

• Germanischer Lloyd

 

• Lloyd´s Register of Shipping

 

• Registro Italiano Navale (pending)

 

• Russian Maritime Register of Shipping

 


 TOP