Applications
For inside and outside use in railway vehicles. Installation in cable ducts or tubes.
Current-carrying capacity acc. to EN 50343 as well as VDE 0298 part 5. Satisfies performance requirements to Hazard Level 4 acc. to EN 45545-1
On request available: completely pre-assembled flexible cables with plugs and sealing ends, electrically tested.
Design
1. Conductor
Flexible stranded tinned copper, acc. to DIN VDE 0295 / IEC 60228
/ HD 383 class 5
2. Inner conductive layer
conductive rubber
3. Insulation
HEPR, type EI110 acc. to EN 50264-1
high voltage compound, ozone resistant
4. Outer conductive layer
conductive rubber (Thermo-Strip)
5. Screen
single wires, tinned (Ø 0,6 mm), separator
6. Outer sheath
Special cross-linked EVA, rubber type EM104 acc. to EN 50264-1,
oil, diesel-oil, ozone and uv resistant
Cable marking
Ink marking white e.g.:
RHEYHALON VDE-Reg.-Nr. 7969 (N)TMCGCHXOE 1x95mm² RF/16 25/45 kV Year
Additional Standards
DIN 5510 part 1, flame protection class 1, 2, 3 and 4
BS 6853
|