español Login Get Registered Catalog Browser Contact Us
Global expert in cables and cabling system

About Nexans

Products and Solutions

Customer Service

Work at Nexans

News and Press

Go

RHEYHALON (N)HXSLOE-OZ / -JZ 300/500 (550) V

Send link to this page print Your Nexans contact on this page
RHEYHALON (N)HXSLOE-OZ / -JZ 300/500 (550) V EN 50264-3-2
Halogenfree sheathed multicore control cable
300/500 V
Standards
International  EN 50264-3-2
National  BS 6853; DIN 5510-1; DIN VDE 0295; DIN VDE 0298
Description

Applications

For use in railway vehicles (locomotives, trains, trolley busses), switching stations and control panels. Installation in cable ducts, tubes and outside (protected).
Current carrying capacity acc. to EN 50343 as well as VDE 0298 part 4.
Serves request acc. to EN 45545-1.

 

Design

1. Conductor

Flexible stranded tinned copper, class 5 acc. to DIN VDE 0295 / IEC 60228
/ HD 383

2. Insulation

Double layer insolation acc. to type EI110/El109 (EM104) acc. to EN 50264-1
oil and diesel-oil resistant

6. Outer sheath

Special cross-linked EVA, rubber type EM104 acc. to EN 50264-1,
oil, diesel-oil, ozone and uv resistant
Colour: black

 

Cable marking

e.g.: RHEYHALON VDE-Reg.Nr. 7967 (N)HXSLOE-OZ EN 50264-3-2 300V
        3x1,5 MM FA-Nr. ...
 

Core colours

(…OZ) – black cores with white numbers
(…JZ) – black cores with white numbers and one green/yellow core

 

Additional standards

DIN 5510 part 1: Flame protection class 1, 2, 3 and 4
BS 6853 (on request)


 TOP
Characteristics
Construction characteristics
Halogen free IEC 60754-1  
Usage characteristics
Operating temperature, range -40 .. 90°C  
Gases corrosivity No acc. to EN 50267-2-2  
Gases toxicity innocuous EN 50305-9.2  
Flame retardant EN 60332-1-2 & EN 60332-3-24 & EN 60332-3-25  
Smoke density EN/IEC 61034-2  
Standard EN  
Bending factor when installed 4(xD)  
Bending factor when laying 5(xD)  
Oil resistance Yes  
Ozone resistance Yes  
U.V resistance Yes  

 TOP
Your selection
Wire colour  
Number of cores  
Conductor cross-section  mm²
Minimum outer diameter  mm
Maximum outer diameter  mm
Fire load  kWh/m
Approximate weight  kg/km
Apply
Reset
Results   24/24
Select all Items Nexans ref. Wire colour Nb. of cores Cross section (mm²) Min. outer diam. (mm) Max. outer diam. (mm) Fire load (kWh/m) Approx. weight (kg/km)
79470916 JZ 3 1 5.5 5.9 0.2 65
79470076 JZ 3 1.5 6.5 7.1 0.28 90
79470315 JZ 5 1.5 7.9 8.5 0.4 140
79470917 JZ 7 1.5 9.4 10.2 0.65 200
79470500 JZ 9 1.5 11.6 12.4 0.9 290
79470194 JZ 18 1.5 14.2 15.2 1.2 420
79471051 JZ 3 2.5 7.2 7.6 0.35 120
79470938 JZ 5 2.5 8.7 9.3 0.5 190
79470451 JZ 18 2.5 16.3 17.5 1.2 600
79470452 JZ 25 2.5 19.6 21.0 1.6 800
79470310 OZ 2 0.75 4.6 5.0 0.16 45
79470355 OZ 2 1 5.3 5.7 0.18 53
79470707 OZ 2 1.5 6.1 6.7 0.25 75
79470420 OZ 3 1.5 6.5 7.1 0.28 90
79470706 OZ 4 1.5 7.3 8.0 0.34 130
79471098 OZ 5 1.5 7.9 8.5 0.4 140
79470705 OZ 6 1.5 8.5 9.3 0.55 165
79470501 OZ 7 1.5 9.4 10.2 0.65 200
79470711 OZ 9 1.5 11.6 12.4 0.9 290
79470708 OZ 15 1.5 13.4 14.2 1 360
79470709 OZ 20 1.5 15.0 16.0 1.3 460
79470710 OZ 2 2.5 6.8 7.2 0.3 95
79470421 OZ 6 2.5 9.7 10.3 0.55 240
79470422 OZ 6 4 11.7 15.5 1.2 340
Add to favorites

 TOP
Electrical properties

Nominal voltage 

Uo/U (Umax) = 300/500 (550) V

Max. operating voltage (d.c.)                                                         

Uo = 450 V DC

Testing a.c. voltage (5 minutes) 

U = 2 kV


Max. operating temperature at conductor

Conductor at normal operation

≤ 90 °C/250.000 h

 

≤ 120 °C/20.000 h

Overload 

≤ 160 °C / 50 h

Conductor under short-circuit conditions (tinned)

≤ 200 °C


 TOP
Selling delivery information
  • Other cross-sections on request.

  •  

  • Special conditions relating temperature and bending radii (e.g. by compelled guidance into cluthes, wagon transition and boogies) on request.