MPRXCX® 331 0.6/1 (1.2) kV

Send link to this page print Your Nexans contact on this page
MPRXCX® 331 0.6/1 (1.2) kV Halogen Free, Fire Resistant Power Cables with screen (amour) 0.6/1 kV
Standards
International  IEC 60092-351; IEC 60092-353; IEC 60092-359; IEC 60331-21 ; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034
Description

Applications

For fixed installation on ships and offshore-units at all levels and open deck in safety circuits, where fire resistance is required.

The good screening qualities of the copper braid also reduce radio interferences and electrical influences to electronic installations.

The cables meet the fire characteristics acc. to IEC 60331 as well as the flame test requirement for bunched cables acc. to IEC 60332-3-22 and IEEE 45-18.13. This follows the intention of the SOLAS requirements.

All cables materials are free of halogens. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, these cables are especially suitable for the installation on passenger ships.

Design

  1. Conductor: stranded bare copper class 2
  2. Insulation: mica tape + XLPE (cross linked polyethylene)
  3. Inner covering (lapped)
  4. Armouring: bare copper braid, separator tape (optional)
  5. Outer sheath: polyolefin, colour: orange

Marking

e. g.: l NEXANS l MPRXCX 331 3x1,5 0,6/1 kV 90°C IEC 60092-353 IEC 60332-3-22 IEC 60331 YEAR *CE* + Metric Marking

Core Identification

In line with DIN VDE 0293-308
1 core: black
2 cores: blue/brown
3 cores: brown/black/grey
4 cores: blue/brown/black/grey
5 to 24 cores cables: all cores white coloured, printed with black numbers, starting in center with 1.
Cables with 3 cores and more also with green-yellow core (has to be stated in order).


 TOP
Characteristics
Construction characteristics
Conductor material Bare copper  
Conductor flexibility Stranded class 2  
Halogen free IEC 60754-1  
Insulation XLPE + Mica tape  
Protection Filler (optional)  
Outer sheath Polyolefin  
Armour type Bare copper braid  
Sheath colour Orange  
Electrical characteristics
Rated Voltage Uo/U (Um) 0.6/1 kV  
Maximum operating voltage 1.2kV  
Test voltage 3500V  
Usage characteristics
Max. conductor temperature in service 90°C  
Short-circuit max. conductor temperature 250°C  
Minimum installation temperature -10°C  
Minimum operating temperature -35°C  
Flame retardant IEC 60332-3 Cat. A  
Fire resistant IEC 60331-21  
Smoke density IEC 61034  
Gases corrosivity IEC 60754-2  
Gases toxicity No toxicity to IEC 60754-1  
Standard IEC  

 TOP
Your selection
Number of cores  
Conductor cross-section  mm²
Minimum outer diameter  mm
Maximum outer diameter  mm
Approximate weight  kg/km
Apply
Reset
Results   37/37
Select all Items Nexans ref. Name Nb. of cores Cross section (mm²) Min. outer diam. (mm) Max. outer diam. (mm)
25493126 MPRXCX® 331 3 x 1.5 mm² 3 1.5 10.5 13.0
25493132 MPRXCX® 331 3 x 2.5 mm² 3 2.5 11.5 14.0
25493163 MPRXCX® 331 1 x 120 mm² 1 120 20.5 23.5
25493172 MPRXCX® 331 1 x 25 mm² 1 25 11.5 14.0
25493173 MPRXCX® 331 1 x 35 mm² 1 35 12.5 15.0
25493174 MPRXCX® 331 1 x 50 mm² 1 50 14.5 17.0
25493175 MPRXCX® 331 1 x 70 mm² 1 70 16.5 19.0
25493176 MPRXCX® 331 1 x 95 mm² 1 95 18.5 21.5
25493156 MPRXCX® 331 12 x 1.5 mm² 12 1.5 18.5 21.5
25493105 MPRXCX® 331 19 x 1.5 mm² 19 1.5 21.5 24.5
25493167 MPRXCX® 331 2 x 1.5 mm² 2 1.5 10.0 12.5
25493167 MPRXCX® 331 2 x 10 mm² 2 10 15.0 17.5
25493183 MPRXCX® 331 2 x 16 mm² 2 16 17.5 20.0
25493044 MPRXCX® 331 2 x 2.5 mm² 2 2.5 11.0 13.5
25493184 MPRXCX® 331 2 x 25 mm² 2 25 21.0 23.5
25493181 MPRXCX® 331 2 x 4 mm² 2 4 12.0 14.5
25493182 MPRXCX® 331 2 x 6 mm² 2 6 13.0 15.5
25493142 MPRXCX® 331 3 x 10 mm² 3 10 16.5 19.0
25493185 MPRXCX® 331 3 x 120 mm² 3 120 37.0 41.0
25493144 MPRXCX® 331 3 x 16 mm² 3 16 18.5 21.0
25493146 MPRXCX® 331 3 x 25 mm² 3 25 22.5 25.0
25493148 MPRXCX® 331 3 x 35 mm² 3 35 24.0 27.0
25493138 MPRXCX® 331 3 x 4 mm² 3 4 12.5 15.0
25493155 MPRXCX® 331 3 x 50 mm² 3 50 26.5 29.5
25493140 MPRXCX® 331 3 x 6 mm² 3 6 14.5 17.0
25493150 MPRXCX® 331 3 x 70 mm² 3 70 30.5 33.5
25493151 MPRXCX® 331 3 x 95 mm² 3 95 34.0 37.5
25493127 MPRXCX® 331 4 x 1.5 mm² 4 1.5 11.5 14.0
25493143 MPRXCX® 331 4 x 10 mm² 4 10 18.0 20.5
25493145 MPRXCX® 331 4 x 16 mm² 4 16 20.5 23.0
25493133 MPRXCX® 331 4 x 2.5 mm² 4 2.5 12.5 15.0
25493162 MPRXCX® 331 4 x 25 mm² 4 25 24.5 27.5
25493164 MPRXCX® 331 4 x 35 mm² 4 35 26.5 29.5
25493139 MPRXCX® 331 4 x 4 mm² 4 4 14.5 17.0
25493141 MPRXCX® 331 4 x 6 mm² 4 6 15.5 18.0
25493095 MPRXCX® 331 5 x 1.5 mm² 5 1.5 12.5 15.0
25493040 MPRXCX® 331 7 x 1.5 mm² 7 1.5 14.0 16.5
Add to favorites

 TOP
Additional Cable Characteristics

Minimum internal bending radius

 

- For all diameter

6 x cable diameter

 

 

Current ratings for continuous operation and further hints for cable installation

 

are according to IEC 60092-352

 


Approval

Type Approval Certificates   

 

• American Bureau of Shipping

 

• Bureau Veritas

 

• Det Norske Veritas 

 

• Germanischer Lloyd

 

• Lloyd´s Register of Shipping

 

• Registro Italiano Navale (pending)

 

• Russian Maritime Register of Shipping

 


 TOP
MPRXCX® 331 0.6/1 (1.2) kV   ABS Certificate valid until 04.01.2011 (119 kB)
MPRXCX® 331 0.6/1 (1.2) kV   DNV Certificate valid until 30.06.2009 (210 kB)
MPRXCX® 331 0.6/1 (1.2) kV   GL Certificate valid until 22.03.2011 (20 kB)
MPRXCX® 331 0.6/1 (1.2) kV   RMRS Certificate valid until 26.04.2011 (93 kB)
MPRXCX® 331 0.6/1 (1.2) kV   BV Certificate valid until 26.05.2013 (637 kB)

Nexans © copyright 2001 - 2012   Legal Notice | Contact Us | Site Map