español Login Get Registered Catalog Browser Contact Us
Global expert in cables and cabling system

About Nexans

Products and Solutions

Customer Service

Work at Nexans

News and Press

Go

FMGCH-F 150/250 V

Send link to this page print Your Nexans contact on this page
FMGCH-F 150/250 V Halogen Free, Fire Resistant Communication Cables with screen (armour) 150/250 V
Standards
International  IEC 60092-351; IEC 60092-359; IEC 60092-375; IEC 60331-21 ; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034
National  DIN 89159; DIN 89159/98
Description

Applications

For fixed installations in communication, radio, control, and data processing facilities on ships and offshore units in all locations, on open decks and in safety circuits, where fire resistance is required.

The cables meet the fire characteristics acc. to IEC 60331-21 as well as the flame test requirements on bunched cables acc. to IEC 60332-3-22 and IEEE 45-18.13, and perform of the SOLAS requirements.

All cable materials are free of halogens. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, these cables are especially suitable for the installation on passenger ships.

 

Design

  1. Conductor: stranded bare copper (7 wires), class 2
  2. Insulation: HEPR (hardgrade ethylene propylene rubber)
  3. Laying up: pair stranding (2 pair cable=quad stranding)
  4. Armouring: separator tape, bare copper braid, separator tape (optional)
  5. Outer sheath: polyolefin, colour: orange

 

Marking

e.g.: l NEXANS l FMGCH-F 250 V 85°C DIN 89159 IEC 60092-375 IEC 60332-3-22 IEC 60331 HALOGENFREE 19x2x0,75 mm2 + Metric Marking

 

Core Identification

Colour of each pair: white-blue
The cores or each pair are printed with same numbers, starting in centre with number 1


 TOP
Characteristics
Construction characteristics
Conductor material Bare copper  
Conductor flexibility Stranded class 2  
Insulation HEPR  
Armour type Bare copper braid  
Outer sheath Polyolefin  
Sheath colour Orange  
Halogen free IEC 60754-2  
Electrical characteristics
Test voltage 1500V  
Rated Voltage Uo/U (Um) 150 / 250 V  
Usage characteristics
Max. conductor temperature in service 85°C  
Flame retardant IEC 60332-3 Cat. A  
Smoke density IEC 61034  
Gases corrosivity No IEC 60754-2  
Gases toxicity No toxicity to IEC 60754-1  
Electro magnetic interference resistance Yes  
Short-circuit max. conductor temperature 250°C  
Fire resistant IEC 60331-21  
Minimum operating temperature -35°C  
Standard IEC  
Minimum installation temperature -10°C  

 TOP
Your selection
Number of pairs  
Conductor cross-section  mm²
Minimum outer diameter  mm
Maximum outer diameter  mm
Approximate weight  kg/km
Apply
Reset
Results   8/8
Select all Items Nexans ref. Name nb pairs Cross section (mm²) Min. outer diam. (mm) Max. outer diam. (mm)
25208804 FMGCH-F 1 x 2 x 0.75 mm² 1 0.75 9.5 10.5
25208704 FMGCH-F 10 x 2 x 0.75 mm² 10 0.75 21.0 23.0
25208604 FMGCH-F 14 x 2 x 0.75 mm² 14 0.75 27.0 29.0
25209704 FMGCH-F 19 x 2 x 0.75 mm² 19 0.75 28.0 30.0
25208504 FMGCH-F 2 x 2 x 0.75 mm² 2 0.75 10.0 11.0
25209604 FMGCH-F 24 x 2 x 0.75 mm² 24 0.75 30.0 33.0
25209504 FMGCH-F 4 x 2 x 0.75 mm² 4 0.75 14.5 16.0
25208904 FMGCH-F 7 x 2 x 0.75 mm² 7 0.75 18.5 20.5
Add to favorites

 TOP
Additional Cable Characteristics

Minimum internal bending radius

 

- For all diameter

6 x cable diameter

 

 

Conductor resistance

≤ 26.0  / km

Insulation resistance

> 1100 MOhm x km

Transfer impedance at 10 MHz

 

1- and 2- pair cable

< 80 mOhm / m

4-pair cable

< 60 mOhm / m

7- to 24-pair cable

< 50 mOhm / m

 

 

Current ratings for continuous operation and further hints for cable installation

 

are according to IEC 60092-352

 


Approval

Type Approval Certificates   

 

• American Bureau of Shipping

 

• Bureau Veritas

 

• Det Norske Veritas 

 

• Germanischer Lloyd

 

• Lloyd´s Register of Shipping

 

• Registro Italiano Navale (pending)

 

• Russian Maritime Register of Shipping

 


 TOP