español Login Get Registered Catalog Browser Contact Us
Global expert in cables and cabling system

About Nexans

Products and Solutions

Customer Service

Work at Nexans

News and Press

Go

NTS-N 4-Core Type, 6-35 kV(7.2-42 kV)

Send link to this page print Your Nexans contact on this page
NTS-N 4-Core Type, 6-35 kV(7.2-42 kV) The standard trailing cables are suitable for use on sprial and cylindrical drums, the axes of which are vertical to the direction of motion during reeling operation with a moving speed of up to 60 m/min.
Standards
National  DIN VDE 0207 part 20; DIN VDE 0207 part 20; DIN VDE 0207 part 21; DIN VDE 0207 part 21; DIN VDE 0250 part 813; DIN VDE 0250 part 813
Description

Construction

Phase core:

Copper conductor, finely stranded, tinned - inner conducter layer of conductive rubber, insulation of dielectrical and thermal high quality, ozone resistant ethylene-propylene rubber (EPR), compound type 3G13, outer conductive layer of conductive ruber (thermo-strip); conductive layers and insulation are applied and cross-linked in one process (triple extrusion).

Protection core:

Copper conductor, finely stranded, tinned- jacket of conductive rubber.

Three phase cores and one protection core laid up - inner sheath filling the assembled cores, compound type GM1b - outer sheath of chlorinated rubber like polychloreoprene (CR), oil resistant and flame retardant, compound type 5GM3

Core colours

Phase cores natural shade with outer black conductive layer

Sheath Colour

Red


 TOP
Characteristics
Construction characteristics
Conductor material Tinned copper  
Conductor flexibility Stranded  
Inner sheath Compound type GM1b  
Material of filler / inner sheath Conductive rubber  
Insulation EPR compound type 3GI3  
Material of the external semi-conductor Conductive rubber  
Outer sheath Chlorinated rubber compound type 5GM3  
Dimensional characteristics
Number of cores 4  
Number of phases 3  
Number of protection cores 1.0  
Usage characteristics
Maximum operating temperature 90°C  
Minimum operating temperature -25°C  
Ozone resistance Yes  
Oil resistance Yes  
Flame retardant Yes  

 TOP
Your selection
Rated Voltage Uo/U (Um)  
Conductor cross-section  mm²
Apply
Reset
Results   69/69
Select all Items Nexans ref. Name Rated Voltage Uo/U (Um) Cross section (mm²)
NTS-N 4-core type 12/20 kV 3x120 /120 12/20 kV 120
NTS-N 4-core type 12/20 kV 3x150 /150 12/20 kV 150
NTS-N 4-core type 12/20 kV 3x16 /16 12/20 kV 16
NTS-N 4-core type 12/20 kV 3x185 /185 12/20 kV 185
NTS-N 4-core type 12/20 kV 3x240 /240 12/20 kV 240
NTS-N 4-core type 12/20 kV 3x25 /25 12/20 kV 25
NTS-N 4-core type 12/20 kV 3x35 /35 12/20 kV 35
NTS-N 4-core type 12/20 kV 3x50 /50 12/20 kV 50
NTS-N 4-core type 12/20 kV 3x70 /70 12/20 kV 70
NTS-N 4-core type 12/20 kV 3x95 /95 12/20 kV 95
NTS-N 4-core type 14/25 kV 3x120 /120 14 / 25 kV 120
NTS-N 4-core type 14/25 kV 3x150 /150 14 / 25 kV 150
NTS-N 4-core type 14/25 kV 3x185 /185 14 / 25 kV 185
NTS-N 4-core type 14/25 kV 3x240 /240 14 / 25 kV 240
NTS-N 4-core type 14/25 kV 3x25 /25 14 / 25 kV 25
NTS-N 4-core type 14/25 kV 3x35 /35 14 / 25 kV 35
NTS-N 4-core type 14/25 kV 3x50 /50 14 / 25 kV 50
NTS-N 4-core type 14/25 kV 3x70 /70 14 / 25 kV 70
NTS-N 4-core type 14/25 kV 3x95 /95 14 / 25 kV 95
NTS-N 4-core type 18/30 kV 3x120 /120 18/30 kV 120
NTS-N 4-core type 18/30 kV 3x150 /150 18/30 kV 150
NTS-N 4-core type 18/30 kV 3x185 /185 18/30 kV 185
NTS-N 4-core type 18/30 kV 3x240 /240 18/30 kV 240
NTS-N 4-core type 18/30 kV 3x25 /25 18/30 kV 25
NTS-N 4-core type 18/30 kV 3x35 /35 18/30 kV 35
NTS-N 4-core type 18/30 kV 3x50 /50 18/30 kV 50
NTS-N 4-core type 18/30 kV 3x70 /70 18/30 kV 70
NTS-N 4-core type 18/30 kV 3x95 /95 18/30 kV 95
NTS-N 4-core type 20/35 kV 3x120 /120 20 / 35 kV 120
NTS-N 4-core type 20/35 kV 3x150 /150 20 / 35 kV 150
NTS-N 4-core type 20/35 kV 3x185 /185 20 / 35 kV 185
NTS-N 4-core type 20/35 kV 3x240 /240 20 / 35 kV 240
NTS-N 4-core type 20/35 kV 3x25 /25 20 / 35 kV 25
NTS-N 4-core type 20/35 kV 3x35 /35 20 / 35 kV 35
NTS-N 4-core type 20/35 kV 3x50 /50 20 / 35 kV 50
NTS-N 4-core type 20/35 kV 3x70 /70 20 / 35 kV 70
NTS-N 4-core type 20/35 kV 3x95 /95 20 / 35 kV 95
NTS-N 4-core type 3,6/6 kV 3x10 /10 3.6/6 kV 10
NTS-N 4-core type 3,6/6 kV 3x120 /120 3.6/6 kV 120
NTS-N 4-core type 3,6/6 kV 3x150 /150 3.6/6 kV 150
NTS-N 4-core type 3,6/6 kV 3x16 /16 3.6/6 kV 16
NTS-N 4-core type 3,6/6 kV 3x185 /185 3.6/6 kV 185
NTS-N 4-core type 3,6/6 kV 3x240 /240 3.6/6 kV 240
NTS-N 4-core type 3,6/6 kV 3x25 /25 3.6/6 kV 25
NTS-N 4-core type 3,6/6 kV 3x35 /35 3.6/6 kV 35
NTS-N 4-core type 3,6/6 kV 3x50 /50 3.6/6 kV 50
NTS-N 4-core type 3,6/6 kV 3x70 /70 3.6/6 kV 70
NTS-N 4-core type 3,6/6 kV 3x95 /95 3.6/6 kV 95
NTS-N 4-core type 6/10 kV 3x10 /10 6/10 kV 10
NTS-N 4-core type 6/10 kV 3x120 /120 6/10 kV 120
NTS-N 4-core type 6/10 kV 3x150 /150 6/10 kV 150
NTS-N 4-core type 6/10 kV 3x16 /16 6/10 kV 16
NTS-N 4-core type 6/10 kV 3x185 /185 6/10 kV 185
NTS-N 4-core type 6/10 kV 3x240 /240 6/10 kV 240
NTS-N 4-core type 6/10 kV 3x25 25 6/10 kV 25
NTS-N 4-core type 6/10 kV 3x35 /35 6/10 kV 35
NTS-N 4-core type 6/10 kV 3x50 /50 6/10 kV 50
NTS-N 4-core type 6/10 kV 3x70 /70 6/10 kV 70
NTS-N 4-core type 6/10 kV 3x95 /95 6/10 kV 95
NTS-N 4-core type 8,7/15 kV 3x120 /120 8.7/15 kV 120
NTS-N 4-core type 8,7/15 kV 3x150 /150 8.7/15 kV 150
NTS-N 4-core type 8,7/15 kV 3x16 /16 8.7/15 kV 16
NTS-N 4-core type 8,7/15 kV 3x185 /185 8.7/15 kV 185
NTS-N 4-core type 8,7/15 kV 3x240 /241 8.7/15 kV 240
NTS-N 4-core type 8,7/15 kV 3x25 /25 8.7/15 kV 25
NTS-N 4-core type 8,7/15 kV 3x35 /35 8.7/15 kV 35
NTS-N 4-core type 8,7/15 kV 3x50 /50 8.7/15 kV 50
NTS-N 4-core type 8,7/15 kV 3x70 /70 8.7/15 kV 70
NTS-N 4-core type 8,7/15 kV 3x95 /95 8.7/15 kV 95
Add to favorites

 TOP
Selling delivery information
Cable fittings

Cables can be supplied with compatible sealing ends, if required (test certificate incl.)

Data for further types upon request

Nexans © copyright 2001 - 2012   Legal Notice | Contact Us | Site Map