NYCY Three-, four and multicore PVC-insulated cables
Standards
National  DIN VDE 0276 part 603; DIN VDE 0276 part 627
Description

Construction

conductor of solid copper wire - PVC insulation - extruded or lapped inner covering - concentric conductor of copper wires and copper tape, applied helically - PVC sheath

Application

in ground, outdoors, in water, in concrete, indoors, and in cable ducts where no mechanical damage is to be expected


 TOP
Characteristics
Construction characteristics
Conductor material Copper  
Insulation PVC  
Conductor shape Circular solid (RE)  
Concentric conductor Copper wires and helical copper tape  
Outer sheath PVC  
Dimensional characteristics
Average sheath thickness 1.8mm  
Electrical characteristics
Rated Voltage Uo/U (Um) 0.6/1 kV  
Maximum operating voltage 1.2kV  
Usage characteristics
Bending factor when laying 12(xD)  
Minimum installation temperature -5°C  
Max. conductor temperature in service 90°C  
Short-circuit max. conductor temperature 160°C  

 TOP
Your selection
Maximum outer diameter  mm
Average insulation thickness  mm
Approximate weight  kg/km
Permissible current rating when buried  A
Permissible current rating in open air  A
Number of cores  
Conductor cross-section  mm²
Apply
Reset
Results   33/33
Select all Items Nexans ref. Name Max. outer diam. (mm) Av. insul. thickness (mm) Approx. weight (kg/km) Current rating, buried (A) Perm. current rating open air (A)
6... NYCY 2 x 1.5 RE/1.5 12.2 0.8 200
6... NYCY 2 x 2.5 RE/2.5 13.0 0.8 240
6... NYCY 2 x 4 RE/4 14.8 0.8 330
6... NYCY 2 x 6 RE/6 15.7 0.8 400
6... NYCY 3x1.5 RE/1.5 17.0 0.8 290 27 20
6... NYCY 3x2.5 RE/2.5 18.0 0.8 350 36 26
6... NYCY 3x4 RE/4 18.0 1.0 480 47 34
6... NYCY 3x6 RE/6 20.0 1.0 590 59 44
6... NYCY 4x1.5 RE/1.5 18.0 0.8 330 27 20
6... NYCY 4x2.5 RE/2.5 19.0 0.8 410 36 26
6... NYCY 4x4 RE/4 20.0 1.0 550 47 34
6... NYCY 4x6 RE/6 21.0 1.0 690 59 44
6... NYCY 5 x 1.5 RE/1.5 14.3 0.8 280
6... NYCY 5 x 2.5 RE/2.5 15.4 0.8 360
6... NYCY 7 x 1.5 RE/2.5 19.0 0.8 440
6... NYCY 7 x 2.5 RE/2.5 21.0 0.8 540
6... NYCY 7 x 4 RE/4 23.0 0.8 630
6... NYCY 10x1.5 RE/2.5 23.0 0.8 550
6... NYCY 10 x 2.5 RE/4 25.0 0.8 730
6... NYCY 12x1.5 RE/2.5 24.0 0.8 620
6... NYCY 12 x 2.5 RE/4 25.0 0.8 800
6... NYCY_14x1.5_RE/2.5 25.0 0.8 680
6... NYCY 14 x 2.5 RE/6 26.0 0.8 900
6... NYCY 16 x 1.5 RE/4 20.0 0.8 630
6... NYCY 16 x 2.5 RE/4 21.7 0.8 825
6... NYCY 19 x 1.5 RE/4 28.0 0.8 840
6... NYCY 19 x 2.5 RE/6 29.0 0.8 1090
6... NYCY 24 x 1.5 RE/6 31.0 0.8 1030
6... NYCY 24 x 2.5 RE/10 33.0 0.8 1370
6... NYCY 30 x 1.5 RE/6 32.0 0.8 1180
6... NYCY 30 x 2.5 RE/10 35.0 0.8 1580
6... NYCY 40 x 1.5 RE/10 36.0 0.8 1500
6... NYCY 40x2.5 RE/10 39.0 0.8 1970